Reconstitution

In-use periods, and the ones nobody can give you

A needle blunts on first use. Reuse is uncomfortable, and it is a documented contributor to lipohypertrophy.

Priming — the air shot, the safety test, the two units expelled before the injection — exists for two reasons and both are real. It clears air from the cartridge and needle so that the delivered volume is solution rather than gas, and it confirms that the device is flowing before the dose is dialled. Skipping it does not always cost a dose, which is exactly why the habit erodes: the feedback is intermittent. When it does cost, it costs silently, and the person concludes that their week was unusual rather than that their pen was full of air.

What the diluent changes, and what it does not

The diluent has no effect on the arithmetic and a substantial effect on everything else. Bacteriostatic water contains a preservative, conventionally benzyl alcohol at around nine tenths of a per cent, which inhibits microbial growth and is what makes repeated puncture of a multi-dose vial defensible. Sterile water for injection contains no preservative and offers no protection after the first puncture. Sodium chloride solution is isotonic and generally more comfortable on injection, and preserved and unpreserved presentations both exist.

The choice is therefore a sterility decision rather than a convenience one. A vial that will be entered more than once and kept for weeks is a different proposition from a single-use preparation, and the presence or absence of a preservative is the difference.

Two cautions belong here. Benzyl alcohol is not appropriate in all populations and is specifically avoided in neonates. And no preservative rescues poor technique: bacteriostatic means growth-inhibiting, not sterilising, and a stopper swabbed carelessly with a needle passed through a wet surface will introduce organisms that the preservative was never intended to handle. The diluent is a margin, not a permission.

Priming, and what skipping it costs

Pen devices require a priming step — commonly a dial to two units and an expulsion until a drop appears at the needle tip — before each injection. It serves two functions: expelling air that has accumulated in the cartridge and needle, and confirming that the device and needle are patent before a dose is dialled.

Skipping it produces an intermittent underdose. Air occupies part of the delivered volume, so some of the dialled dose is gas. Because the loss is variable and invisible, the person experiences an occasional week that felt different rather than a device error, and the habit erodes precisely because the feedback is unreliable.

Two adjacent points belong with it. A pen needle should be attached immediately before use and removed immediately after, because a needle left in place allows solution to leak out and air to be drawn in, which is how cartridges come to contain air in the first place. And the ten-second hold at the end of an injection — plunger fully depressed, needle still in the skin — exists because delivery is not instantaneous at these bore sizes, and withdrawing early leaves part of the dose on the skin. Both are omitted routinely.

Lipohypertrophic tissue hurts less to inject into. That is precisely why people keep injecting into it.

On rotation

Aseptic technique, in four steps

Wash hands. Swab the vial stopper with seventy per cent alcohol and let it dry. Swab the injection site and let that dry. Use a new sterile needle for every entry into the vial and every injection.

Each step has a reason that is worth knowing, because steps with unexplained reasons are the ones that get dropped. The stopper is the sterile barrier of a multi-dose vial and a needle passed through a contaminated or still-wet stopper carries organisms directly into the solution. Alcohol works by evaporation as much as by contact, so a wet surface has not been disinfected — and injecting through wet alcohol stings, which is frequently misattributed to the drug. A needle that has already pierced a rubber stopper is blunted and no longer sterile.

What none of this can do is make an unknown preparation safe. Aseptic technique protects a sterile solution from contamination during handling; it does not sterilise a solution that arrived contaminated, and it does nothing whatever about bacterial endotoxin, which is heat-stable, filter-passing and invisible to any purity assay. Research-use-only material is not manufactured, tested or released to any human sterility standard, and careful technique does not change that.

Reconstitution reference: micrograms of peptide per U-100 unit
Vial mass1.0 mL diluent2.0 mL diluent2.5 mL diluent5.0 mL diluent
2 mg20 µg/unit10 µg/unit8 µg/unit4 µg/unit
5 mg50 µg/unit25 µg/unit20 µg/unit10 µg/unit
10 mg100 µg/unit50 µg/unit40 µg/unit20 µg/unit
15 mg150 µg/unit75 µg/unit60 µg/unit30 µg/unit
20 mg200 µg/unit100 µg/unit80 µg/unit40 µg/unit
Arithmetic only, and correct only if the stated vial mass is accurate. Where peptide content has not been independently measured, treat the labelled mass as an upper bound and the resulting figure as an estimate.

Storage, and the in-use period nobody can give you

Lyophilised peptide is generally stored refrigerated at two to eight degrees, and is considerably more stable dry than in solution — which is the entire reason it is supplied as a powder. After reconstitution, degradation proceeds by hydrolysis, oxidation, aggregation and adsorption to container surfaces, at rates depending on sequence, buffer, temperature, light exposure and headspace.1

For licensed products the in-use period is established by formal stability testing and printed on the carton, commonly twenty-eight days for a pen in use. For a peptide reconstituted at home there is no such study, and the numbers circulating in this market are extrapolations from other molecules, other buffers and other containers.

Three practical points survive that uncertainty. Cold slows every degradation route, so refrigeration is unambiguously better than ambient storage. Agitation promotes aggregation, so a vial should be swirled or the diluent run down the wall rather than shaken. And repeated temperature cycling — out for a dose, back in the door of the fridge, out again — is worse than steady cold, which argues against storing a vial in the door.

Anybody quoting a precise expiry for a home-reconstituted peptide is quoting a guess. The Journal would rather say so than repeat a number that sounds authoritative.

Sharps disposal

A used needle is a biohazard to whoever encounters it next, most often a waste worker. In most jurisdictions disposal of sharps in household waste is prohibited, and in all of them it is a route by which a stranger is injured.

The mechanism is simple and free almost everywhere: a rigid, puncture-resistant sharps container, filled to the marked line and no further, returned to a community pharmacy, a local authority collection point, a needle-exchange service or a clinical waste scheme. Improvised containers — a detergent bottle, a coffee tin — are widely used and generally accepted by collection services when rigid and sealed, though a purpose-made container is inexpensive.

Needle-clipping devices exist and remove the sharp tip. They reduce but do not eliminate the hazard and do not remove the disposal obligation.

The Journal raises this for a specific reason. We have heard from readers with two or three years of accumulated sharps in a drawer, kept there because they did not know where to take them and did not want to explain what they were for. Collection services are not interested in the contents of your vials. That is a real barrier built entirely out of anticipated judgement, and it is worth naming so that it can be dismissed.

Needle reuse

Needle points are manufactured sharp, coated and single-use. A single insertion blunts and deforms the tip measurably; electron micrographs of reused needles show visible damage after one use and substantial deformation after several. Reuse is more painful, produces more tissue trauma, and is a documented risk factor for lipohypertrophy.2

It is also extremely common, for reasons that are economic rather than ignorant. Needles cost money, they are sometimes hard to obtain without a prescription, and the harm from reuse is cumulative and invisible rather than immediate. A person reusing a needle is usually making a rational short-term decision with a poorly signposted long-term cost.

Two aggravations are worth stating. A needle left attached to a pen between doses allows leakage out and air in, which is a dosing problem as well as a sterility one. And a needle reused into a vial blunts the stopper, coring rubber fragments into the solution over repeated entries.

The Journal reports the practice without moralising about it, and notes that of all the technique failures in this file, this is the one most responsive to needles simply being cheap and available.3

Four things about this that are genuinely unestablished

First, the in-use stability of home-reconstituted peptides. No sequence-specific, buffer-specific, container-specific stability study exists for the great majority of what is sold in this market, and the figures in circulation are extrapolations.

Second, whether the injection-site interchangeability established for licensed acylated agonists holds for material of uncertain formulation. The mechanism suggests it should; nobody has measured it.

Third, the real-world frequency of the errors catalogued above. Our ranking comes from correspondence, which is a self-selected sample that over-represents people who noticed. The denominator is unknown.

Fourth, whether any of the technique measures described here changes outcomes in this specific population. They are supported by anatomical evidence and by the insulin literature; a trial in incretin users has not been done and probably will not be.4

Readers who know of stability data or technique trials we have missed should write to standards@compoundjournal.com. This is one of the files where we would most like to be corrected, because the current state is that millions of injections a week are being given on the basis of transferred evidence and a four-line calculation.

One thing we would like to see changed is trivially achievable. Needles are cheap, and reuse is driven almost entirely by cost and availability rather than by any belief that it is safe. Of every technique failure catalogued above, that is the one most responsive to supply, and the one where the barrier is commercial rather than educational.

References

  1. Manning MC, Chou DK, Murphy BM, Payne RW, Katayama DS. “Stability of protein pharmaceuticals: an update.” Pharmaceutical Research. 2010;27(4):544–575.
  2. Blanco M, Hernández MT, Strauss KW, Amaya M. “Prevalence and risk factors of lipohypertrophy in insulin-injecting patients with diabetes.” Diabetes & Metabolism. 2013;39(5):445–453.
  3. Frid AH, Hirsch LJ, Menchior AR, Morel DR, Strauss KW. “Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.” Mayo Clinic Proceedings. 2016;91(9):1212–1223.
  4. Frid AH, Kreugel G, Grassi G, et al. “New Insulin Delivery Recommendations.” Mayo Clinic Proceedings. 2016;91(9):1231–1255.

Letters to the Editor

4 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

Your rotation advice says site does not affect absorption in this class, and then says to rotate anyway. If absorption is unaffected, why bother?

J. Vasilenko, Chisinau

The Journal replies

Because rotation protects tissue rather than controlling absorption. Repeated injection into one small area produces lipohypertrophy, and absorption from lipohypertrophic tissue is blunted and erratic for any injected depot. Rotation prevents the condition that would make site matter. The advice is consistent; we should have made the causal order clearer.

I have accumulated about eighteen months of used needles in a plastic tub because I did not know where to take them and assumed I would be asked questions. Your paragraph on this is the first time I have seen the situation described rather than lectured about.

K. Sivertsen, Bergen

The Journal replies

Collection services are not interested in what was in the syringe. A pharmacy or local authority sharps point will take a rigid sealed container without inquiry, and the barrier you describe is built entirely of anticipated judgement. We would rather say that plainly than add to the lecturing.

A quibble on your dead-space figure. You give two to seven microlitres for insulin-type needles, which is right for fixed-needle syringes, but the detachable pen needle plus syringe hub combinations sold in this market are considerably worse and you should say so.

S. Bergqvist, Malmö

The Journal replies

Accepted and amended. The figure we gave applies to integrated fixed-needle insulin syringes; detachable arrangements on a luer fitting can retain an order of magnitude more, which at small injection volumes is a substantial loss. The table now distinguishes them.

You spend a page on the four-line calculation and then publish a reconstitution table anyway. Are you not providing exactly the pre-computed number you warned against?

T. Oyelowo, Abeokuta

The Journal replies

A fair catch, and the reason the table carries the note it does. It is indexed by both vial mass and diluent volume precisely so that it cannot be read as a single fixed answer, and it is preceded by the derivation. If we thought a reader would take one figure from it and carry that figure across a change of vial, we would remove it.

Related coverage

Explainers

Gauge, pain and flow rate

Gauge affects pain and flow rate rather than depth. A finer needle is more comfortable and slower, and with a viscous solution the difference is noticeable.

Marguerite Vasseur·7 May 2024·7 min

Patient Notes

Gauge, pain and flow rate

The insulin injection-technique literature is large, well conducted and directly transferable on questions of depth and tissue. We say where it stops transferring.

Perpetua Nwachukwu·6 Mar 2025·12 min