Independent analysis puts a QST exenatide lot at 98.4%, against 95.6% on the certificate
A reminder that a purity figure is the output of a method, and that methods differ.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Page 5 of 7 of this archive, newest first.
A reminder that a purity figure is the output of a method, and that methods differ.
Every degradation pathway accelerates by orders of magnitude on reconstitution, because the solvent that lyophilisation removed is the reagent most of them need.
A reminder that a purity figure is the output of a method, and that methods differ.
What would make a difference is not a regulator. It is three lines on a certificate, all of which are already known to whoever wrote it.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
None of what a checkable identity statement requires is commercially sensitive, and all of it is known to whoever produced the document.
Aggregates dissociate in the mobile phase and are recorded as monomer. Only a size-based separation reports them.
The gap between a defensible recommendation and a confident one is where most of the harm in this subject lives.
A reminder that a purity figure is the output of a method, and that methods differ.
The header identifies the batch, the table records the tests, and the footer says who is answerable. Two of the three are usually incomplete.
Every instrument specification quoted in an advertisement is a best case obtained on a calibration mixture, not on a submitted vial.
Every step between the laboratory report and the product page removes information, and the badge is the last step.
Water is a reactant in hydrolysis, a plasticiser that mobilises the amorphous matrix, and a carrier for everything else. All three matter.
Water is a reactant in hydrolysis, a plasticiser that mobilises the amorphous matrix, and a carrier for everything else. All three matter.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
We set out what is known, what is inferred and what is simply assumed about the fortnight after a vial is opened.
Peptide content is the number that tells you how much drug is in the vial. Almost nobody sells it, almost nobody buys it, and when we paid for it on nine vials the results…
The ionisation method determines the charge states you see, the adducts you must account for, and the modifications you might destroy in the process.
The limit for a parenteral product is calculable from the dose and the body weight in two lines. Almost nobody in this trade performs the calculation.
What the pivotal programmes measured and how often, which is a more defensible template than most published monitoring schedules.