One method is one opinion
Aggregates dissociate in the mobile phase and are recorded as monomer. Only a size-based separation reports them.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Aggregates dissociate in the mobile phase and are recorded as monomer. Only a size-based separation reports them.
Residual moisture is measured routinely in regulated manufacture, is reported almost nowhere in this trade, and predicts long-term stability better than any other single…
The supplier has not disputed the finding. It has not explained the gap either.
The evidence base is one secondary analysis, several small studies and a large amount of extrapolation from bariatric surgery.
Calibration drift is real, unremarkable, and the reason serious laboratories run internal standards.
A needle blunts on first use. Reuse is uncomfortable, and it is a documented contributor to lipohypertrophy.
An orthogonal method separates on a different physical principle, so that species co-eluting in the first are likely to resolve in the second. Two runs of the same method at…
The supplier has not disputed the finding. It has not explained the gap either.
Accreditation to the international competence standard covers the scope a laboratory has been assessed for, which is not necessarily the test you commissioned.
At low concentrations a measurable fraction of peptide can adsorb to glass and plastic surfaces, and the loss is largest exactly where it is least expected.
The result is unremarkable. What the report omits is not.
The report states the gradient, the wavelength and the integration threshold, which is more than most.
The assay is not the problem. The interpretation of a lagging integral as a current measurement is the problem.
The limit for a parenteral product is calculable from the dose and the body weight in two lines. Almost nobody in this trade performs the calculation.
Repeated injection into the same small area produces lipohypertrophy — thickened, rubbery subcutaneous tissue with blunted and erratic absorption. It is common, it is…
Deamidation, oxidation, aggregation and hydrolysis account for nearly all of what happens to a peptide over time. Each has a characteristic residue, a characteristic…
The report states the gradient, the wavelength and the integration threshold, which is more than most.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
Two years ago we ran an anonymised version of this comparison and promised a named one. This is it, with every method printed in full.
The report states the gradient, the wavelength and the integration threshold, which is more than most.