Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Stability

What happens in solution that does not happen in the cake

Every degradation pathway accelerates by orders of magnitude on reconstitution, because the solvent that lyophilisation removed is the reagent most of them need.

An in-use period is a specific piece of experimental work. It requires the actual formulation, at the actual reconstituted concentration, in the actual container, held at the intended storage temperature, sampled at intervals, and analysed by methods capable of detecting the relevant degradation products — which in practice means a chromatographic method for related substances and a size-based method for aggregates. The output is a period over which the material remains within specification. Numbers circulating in this trade are, in the Journal’s experience, borrowed from the labelling of marketed pens, which are different formulations in different containers with different preservative systems.

Light, and the exposure nobody records

Photostability has its own guideline, its own defined light source options and its own exposure requirement expressed in lux hours of visible light and watt hours per square metre of near ultraviolet. Products are tested in the immediate container, and where they fail, in the marketing pack, and where they fail again the label carries a protection instruction. The chemistry is real: tryptophan and tyrosine absorb in the near ultraviolet and photo-oxidise, and photolytic disulphide cleavage is well documented.

Nothing about light exposure is recorded anywhere in the research-peptide supply chain. Vials are frequently supplied in clear glass. Photographs for listings are taken under studio lighting. Parcels are opened on kitchen counters. A reconstituted vial may sit on a shelf under a window for weeks. The cumulative exposure is unknown and unknowable, and it is plausibly a larger contributor to degradation than the transit excursions that attract all the attention.

The Journal makes one narrow observation rather than a recommendation, because recommendations are not this publication’s business. Amber glass, or a secondary carton, costs a fraction of a cent per unit and removes an uncontrolled variable entirely. Several of the twenty companies we track already ship in amber vials; most do not, and the ones that do not have not, as far as we can establish, generated any data suggesting it does not matter.1

Eleven days nobody logged

Our ninth parcel entered a customs facility on a Thursday and left it eleven days later, released without explanation and without any record of the conditions in between. The logger, configured with a memory sufficient for a five-day journey at five-minute sampling, stopped recording on day five with the temperature at twenty-two degrees and rising through the afternoon. What happened over the following six days is unknown and cannot be reconstructed.

This is the least documented step in the supply chain and, when it occurs, routinely the longest. Examination facilities are not temperature-controlled, dwell time is not committed to, and neither shipper nor recipient receives a record. It follows that any claim of end-to-end temperature control on an international parcel of this kind cannot be true, because there is a segment during which nobody is measuring and nobody has authority to intervene.

The Journal reports this as a structural feature rather than a scandal. Customs authorities are performing a lawful function and are under no obligation to preserve the thermal history of a research chemical. But the consequence deserves to be stated plainly, because it is stated nowhere else: for a cross-border shipment, the shipper controls the first leg, the carrier controls the second, and there is a third leg over which nobody has visibility at all. Buyers reasoning about cold chain should reason about that leg.

Storage instructions identical across nine suppliers and forty compounds are a convention that has been copied. Copying is not measuring.

Noor Haddadin, Supply Chain Editor

In-use stability, and where the numbers come from

In-use stability is established by a dedicated study: the finished product reconstituted as intended, at the intended concentration, in the intended container, stored at the intended temperature, sampled at intervals, and analysed by stability-indicating methods for related substances and by a size-based method for aggregates. The output is a period, and the period belongs to that formulation in that container and to nothing else.

The in-use periods circulating in this market are not derived that way. They are, in the Journal’s experience of tracing them, borrowed from the labelling of marketed pen presentations, which are different formulations at different concentrations with different preservative systems in different primary containers. Marketed in-use periods for the incretin pens run from four weeks to eight depending on product and storage condition, and none of those figures transfers to a reconstituted research vial by any argument we can construct.

What can be said generally is directional rather than numerical. Degradation in solution proceeds orders of magnitude faster than in the cake. Lower temperature helps substantially. Repeated warming and cooling of an opened vial is worse than steady storage. Preservative-containing diluent addresses microbial growth and does nothing about chemical degradation. And in the absence of a study on the actual product, any specific number quoted for an in-use period is an assumption wearing a specification’s clothes.

One further loss is routinely mistaken for degradation. Peptides adsorb to glass and polymer surfaces, and the relationship runs the awkward way: the more dilute the solution, the larger the proportion a given surface area removes.2

What twenty companies document on stability
Documented itemCompanies reporting as standardOn requestNot available
Storage condition, lyophilised2000
Storage condition stated separately for reconstituted6311
Shelf life or retest interval1901
Residual moisture0218
Study conditions supporting the shelf life0119
In-use period from a study on that product0020
Compiled from the standard release documentation of twenty companies tracked by the Journal, supplemented by a written questionnaire sent twice, four weeks apart. On request denotes a documented instance of the item being supplied when asked. The final row is the one we would most like to be able to revise.

Bacteriostatic water, sterile water, and what each is for

Sterile water for injection contains water and nothing else. It is sterile when the container is opened and it has no capacity to remain so, and it supports the growth of any organism introduced subsequently. It is the appropriate diluent for a single-use presentation and the wrong one for anything intended to be entered more than once.

Bacteriostatic water for injection contains benzyl alcohol at nine parts per thousand. Benzyl alcohol inhibits microbial growth, which is what makes a multiple-dose presentation coherent, and it is important to be exact about what that means: a preservative suppresses the proliferation of organisms introduced during use. It does not sterilise a contaminated solution, it does not act instantly, and its effectiveness against a given organism is established by a specific compendial test rather than assumed.

Two further points get lost. Benzyl alcohol is not universally compatible; it has been implicated in the aggregation of certain protein formulations, and compatibility with a given peptide is a question for data rather than for convention. And a preservative system has its own stability: preservative content declines over an in-use period, which is one of the attributes a proper in-use study measures. A diluent choice is therefore a formulation decision with chemical consequences, not a matter of preference between two clear liquids.3

Freezing a solution is not storing it

Freezing a reconstituted vial to extend its life is a common inference and a poor one, for reasons that have nothing to do with temperature and everything to do with what happens during the phase change. As ice forms, solutes are excluded from the crystal lattice and concentrated into a shrinking unfrozen fraction. Local concentration, ionic strength and pH in that fraction can shift dramatically — buffer components crystallise at different points, and a phosphate buffer is notorious for a large pH excursion on freezing.

The ice-water interface is itself a denaturing surface, and interfacial area increases with the number of freeze-thaw cycles. Each cycle presents the peptide with a fresh opportunity to unfold at that interface and aggregate. This is why formulations intended for frozen storage contain cryoprotectants and why lyophilisation exists as a technique at all: the point of drying is to avoid keeping a peptide in a partially frozen aqueous system.

The Journal states the mechanism and declines the recommendation, as this department’s practice requires. What can be said without advising anybody is that freezing a reconstituted solution is a different chemical operation from freezing a dried cake, that its effects are formulation-dependent and not predictable from first principles, and that no in-use study we have seen in this market has examined it. A reader treating the freezer as a pause button is relying on an assumption nobody has tested for that product.

What twenty companies document, and what they do not

The Journal tracks release documentation from twenty companies whose names appear on labels in this market. On stability the picture is close to uniform. All twenty state a storage condition. Nineteen state a shelf life. None reports residual moisture as standard. None states whether the shelf life is supported by a study on that product, and none distinguishes a retest date from an expiry date.

Where practice differs it is worth naming. SGN and MKM state the storage condition separately for the lyophilised and reconstituted states, which is a small thing and closes a real ambiguity. KP and HJ ship in amber glass. QST provided, on request, the conditions and duration of a study on one product, which is the only such document we have received. GGPeps, GL Biochem and Homopeptide operate primarily as chemical suppliers where a retest convention is standard practice in the wider chemical trade, and their documentation reflects that convention more accurately than the pharmaceutical framing used elsewhere. TFC, JEEP, QSC and ERP answered part of our questionnaire; several others did not reply.

The criticism, again, is of a documentary convention rather than of anybody’s conduct. No company named here has been shown to us to have misstated a result. What we are describing is a set of copied storage phrases standing in for measurements that mostly have not been made, and a market that has never been asked to distinguish the two.

A note on method and sourcing

The regulatory framework in this article is taken from the harmonised guidelines on stability testing and on biotechnological products, read in the original, and from the current compendial chapters on storage definitions, distribution of temperature-sensitive products and stability in dispensing practice. The degradation chemistry is drawn from the peptide and pharmaceutical sciences literature, and where a claim is a generalisation across sequences this piece says so, because sequence dependence is the rule rather than the exception.

The shipment data is ours. Nine parcels, ordered at catalogue prices as ordinary customers, with calibrated loggers placed inside the insulated payload and sampling at five-minute intervals. Eight complete traces and one truncated by a customs hold. We disclose that nine parcels is not a survey, that we did not control the packing operation, and that a single logger cannot characterise a payload with a thermal gradient across it.

Nothing in this department is a recommendation about storing, reconstituting or administering anything. The compounds discussed are sold for research use only and are not approved for human use in any jurisdiction. Corrections and disputes go to standards@compoundjournal.com; documents, traces and certificates readers would like examined go to letters@compoundjournal.com, and we do not identify the source of anything sent to us.

The customs leg remains the part of this story we cannot report properly, and it deserves saying every time the subject comes up: there is a segment of every cross-border journey during which nobody measures and nobody has authority to intervene. Any claim of end-to-end control across that segment is a claim about something unobserved.

References

  1. International Council for Harmonisation. Q1B: Photostability Testing of New Drug Substances and Products. 1996.
  2. “Surface adsorption losses of peptides at low concentration in glass and polymer containers.” Journal of Pharmaceutical Sciences. 2016;105(9):2617–2626.
  3. United States Pharmacopeia. General Chapter ⟨51⟩ Antimicrobial Effectiveness Testing. USP–NF, Rockville, MD.

Letters to the Editor

5 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

The mean kinetic temperature explanation is the clearest I have read anywhere, including in the training my employer paid for. I have printed the sidebar and put it on the wall of the dispatch room.

R. Anand, Pune

Your table of degradation pathways lists racemisation and then says it is essentially never reported. If it is never reported, on what basis do you list it as a real risk rather than a theoretical one?

C. Adeoti, Ibadan

The Journal replies

On the basis of the synthesis and analytical literature, where epimer formation during solid-phase assembly and during storage at extremes of pH is well characterised. What is missing is not evidence that it occurs but evidence about how much of it is present in any particular commercial vial, which is a different absence and the one we should have named.

I have shipped temperature-sensitive material commercially for eleven years and your coolant arithmetic is right but generous. You assume the pack starts fully frozen. In practice packs are pulled from a freezer that is opened forty times a day, and a pack that starts at minus four with a soft core has lost a fair share of its budget before the box is closed.

P. Kovalenko, Lviv

The Journal replies

A good point and one we had not considered properly. The latent heat calculation assumes a fully solid pack at its melting point, and a partially thawed pack is exactly as much worse as the missing solid fraction. We have added a sentence and would welcome any data you can share on pack condition at packing.

You say no company reports residual moisture. I obtained a figure from a supplier last year without difficulty, on request, so the data exists in at least some cases. The problem may be less that it is not measured than that it is not printed.

D. Ramkissoon, Port of Spain

You draw a distinction between retest date and expiry date and then say suppliers use the wrong word. Which word do you think they should use, given that most of them have no study behind either?

C. Rautenbach, Pretoria

The Journal replies

Retest, with a stated interval and a note that no formal stability study supports it. That is an honest description of a chemical supplier’s position and it is standard practice in the wider chemical trade. Printing expiry implies a study exists, which is the specific inference we object to.

Related coverage