What the sequence tells you about how a peptide will fail
Reversed-phase chromatography runs in an organic, acidic mobile phase that dissociates most non-covalent aggregates on the way to the detector.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Container closure
The Journal has read several hundred certificates from twenty companies. We set out what the documents actually cover, and what a reader is filling in from imagination.
A certificate of analysis for a research peptide is, in the overwhelming majority of cases, a document about chemistry. It reports a chromatographic purity figure, sometimes a mass, occasionally a water content, and it is generated from a few milligrams of powder dissolved in a vial of mobile phase. Nothing in that procedure has any bearing on whether the sealed container it came from holds viable microorganisms, whether the powder carries pyrogenic material from an upstream water system, or whether the stopper has maintained a seal since the day it was crimped. The document is accurate and it is answering a different question.
Consider what happens physically when a certificate is produced. A few milligrams of lyophilised powder are weighed, dissolved in an aqueous mobile phase with an organic modifier, injected onto a reversed-phase column and separated over a programmed gradient while an ultraviolet detector records absorbance. The output is a trace. Software integrates the areas beneath its features, and the main peak area as a proportion of the total becomes the purity figure.
Every step of that procedure is blind to microbial contamination. A bacterial cell contributes no ultraviolet-absorbing peak at any retention time a peptide method would record. Endotoxin, a lipopolysaccharide, is not usefully detected at the wavelengths used for peptide bond absorbance and would in any case be present at a mass fraction several orders of magnitude below any integration threshold in commercial use. A vial holding a hundred colony-forming units and a vial holding none produce chromatograms that no analyst could distinguish.
This is not a defect of the method. Reversed-phase chromatography is an excellent way of determining what proportion of the chromatographically visible material is the intended species, and that is what it is being asked. The defect is in the reading. A document answering one question is being filed as evidence about five.
A sterilising filter is not an unlimited barrier. Its qualification is expressed as a retention capability under a defined challenge — conventionally a high titre of a small bacterial species per square centimetre of membrane — and its performance in use depends on the load presented to it. A bulk solution carrying a heavy microbial burden presents a filter with a harder problem than one carrying a light burden, and it presents a second problem the filter cannot address at all: the endotoxin released by organisms that die upstream passes through the membrane unimpeded.
Regulated manufacture therefore specifies a pre-filtration bioburden limit, tests against it on every batch, and treats an excursion as an investigation rather than a curiosity. The specification is usually expressed in colony-forming units per hundred millilitres, and a well-controlled process runs far below it.
Of the twenty companies the Journal wrote to, four stated that pre-filtration bioburden is determined on every batch, three stated that it is determined periodically, and the remainder did not answer the question. We regard that distribution as the single most informative result of the correspondence, because bioburden testing is inexpensive, is performed on the bulk rather than the finished container, and is the earliest point at which a problem is cheap to fix.
Killing the bacteria does not remove the endotoxin, and may increase the free concentration.
Suppose a batch of ten thousand vials in which one vial in a thousand is contaminated — a rate that would be a serious finding in any regulated operation and is invisible to any buyer. The probability that a single randomly chosen vial is clean is 0.999. The probability that all twenty sampled vials are clean is 0.999 raised to the twentieth power, which is approximately 0.980. The sterility test therefore passes this batch about ninety-eight times in a hundred.
Push the contamination rate up tenfold, to one vial in a hundred, and the test still passes the batch roughly eighty-two times in a hundred. To reach an even chance of detection at a one per cent contamination rate you would need to sample about seventy containers; to have a reasonable prospect of catching a one-in-a-thousand rate you would need to sample several hundred, which for most batches means testing a substantial fraction of the product.
This is not a criticism of the compendial test, which is designed as a final check against gross failure and performs that function. It is the reason no serious manufacturer treats a passed sterility test as the basis of the sterility claim, and the reason that a research supplier offering to have a vial sterility-tested on request is offering something considerably weaker than it sounds.
| Method | Readout | Quantitative | Glucan-sensitive | Animal-derived reagent |
|---|---|---|---|---|
| Gel-clot | Clot / no clot on inversion | Limit test; semi-quantitative by dilution | Yes | Yes |
| Turbidimetric, endpoint | Turbidity at fixed time | Yes | Yes | Yes |
| Turbidimetric, kinetic | Time to defined turbidity | Yes, wide range | Yes | Yes |
| Chromogenic, kinetic | Time to absorbance change | Yes, wide range | Yes | Yes |
| Recombinant factor C | Fluorescence or absorbance | Yes, wide range | No | No |
| All five are described in current compendial chapters, with recombinant reagents now addressed in dedicated chapters rather than solely as alternative methods. Glucan sensitivity is a source of false positives where cellulosic filter media contact the sample. | ||||
Endotoxin is a structural component of the outer membrane of Gram-negative bacteria: a lipopolysaccharide with a lipid A anchor that is the pyrogenic moiety, a core oligosaccharide, and a variable O-antigen chain. It is shed during growth and released in quantity on cell lysis, which means that killing a bacterial population does not remove its endotoxin and may increase the free concentration.
Three physical properties make it a separate discipline. It is thermally robust, surviving autoclave conditions with little loss of pyrogenicity, so terminal sterilisation is not a depyrogenation step. It is small and amphipathic, forming aggregates that pass a 0.22 micron membrane without difficulty, so sterilising filtration is not a depyrogenation step either. And it is active in humans at very low mass — the threshold pyrogenic dose corresponds to something in the region of a nanogram per kilogram of body weight.
The practical consequence is stark. A vial can pass a sterility test, contain no viable organism of any kind, and carry an endotoxin burden many times a defensible parenteral limit, because the organisms responsible died somewhere upstream in a water system, a holding tank or a poorly stored component.1
Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.
We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.
What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.2
The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.
Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.
What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.
The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.
Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.
Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.
Readers should hold two facts together, uncomfortable as the combination is. The frameworks described here — endotoxin limits, sterility assurance, particulate ceilings — govern licensed parenteral medicines, and research-use material is under no obligation to meet them. That is a legal fact about obligation. It is not a reassurance, and nobody involved in the trade has ever suggested it was.
Reversed-phase chromatography runs in an organic, acidic mobile phase that dissociates most non-covalent aggregates on the way to the detector.
The limit for a parenteral product is calculable from the dose and the body weight in two lines. Almost nobody in this trade performs the calculation.
A shallow gradient resolves impurities that a steep one runs into the parent peak. Both methods are legitimate; only one of them can see the small stuff.
The Journal’s standing position: a mass that matches is necessary evidence of identity and nowhere near sufficient.
Residual moisture is measured routinely in regulated manufacture, is reported almost nowhere in this trade, and predicts long-term stability better than any other single…
The two ionisation techniques in general use produce different charge distributions, different adducts and different failure modes. Certificates almost never say which was…