HbA1c and its lag: what a result three months old is telling you
The assay is not the problem. The interpretation of a lagging integral as a current measurement is the problem.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Page 2 of 12 of this archive, newest first.
The assay is not the problem. The interpretation of a lagging integral as a current measurement is the problem.
The ionisation method determines the charge states you see, the adducts you must account for, and the modifications you might destroy in the process.
Weight loss reduces bone mineral density at load-bearing sites. Whether that translates into fractures in this population is unmeasured.
Particulate matter is the oldest quality attribute in injectable manufacture and the one a private buyer is best placed to assess without instrumentation.
Repeated injection into the same small area produces lipohypertrophy — thickened, rubbery subcutaneous tissue with blunted and erratic absorption. It is common, it is…
For licensed products the in-use period is established by stability data. For a peptide reconstituted at home there is no such data, and the honest answer is that nobody…
The argument for a baseline panel is that it makes every subsequent result interpretable. The argument against frequent monitoring is that noise accumulates faster than…
Matching a retention time against a standard is evidence of consistency, not proof of identity. Two different species can elute at the same time on one method.
The most useful single addition to any purity determination is a second separation under a different pH or on a different stationary phase, and the second-most useful is a…
The compendial definitions of cold, controlled cold and controlled room temperature permit specified excursions, and knowing the permitted band is the difference between an…
Purity, content, identity, sterility and endotoxin are five separate determinations. A single sheet of paper carrying one of them is not evidence about the other four.
The Journal has read several hundred certificates from twenty companies. We set out what the documents actually cover, and what a reader is filling in from imagination.
Aggregates dissociate in the mobile phase and are recorded as monomer. Only a size-based separation reports them.
The evidence base is one secondary analysis, several small studies and a large amount of extrapolation from bariatric surgery.
Every additional analyte raises the probability of a flagged result and lowers the average information content of the panel.
Both the reassuring reading and the alarming reading are supportable from the same tables. This piece sets out which is which.
What the renal and hepatic outcome programmes actually measured, and over what duration.
The Journal has read several hundred certificates from twenty companies. The number is almost always there; the method behind it almost never is.
Lyophilisation does not stop degradation. It slows every pathway by removing the solvent that most of them require, and the residue of solvent that remains sets the rate.
An isoaspartate rearrangement changes the molecule and not the mass. A method that confirms identity by molecular weight alone will report it as the parent compound.