A vial can be 99.4 per cent pure and not sterile in the same afternoon
Purity, content, identity, sterility and endotoxin are five separate determinations. A single sheet of paper carrying one of them is not evidence about the other four.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Aseptic fill
Four independent services underpin confidence in this market. All four are competent at chemistry. Microbiology is a different accreditation, a different facility and a different fortnight.
Four independent testing services carry most of the weight of trust in the research-peptide trade: Janoshik, Medutest, PeptideMeter and VendorInvestigate. Between them they have done more to raise documentation standards in this market than any regulator has, and the Journal says so plainly because the criticism that follows is narrower than it might otherwise appear. All four are chemistry operations. Their instruments separate, detect and identify molecules. None of the four is primarily a microbiology laboratory, and microbiology is where the questions in this piece live.
Consider what happens physically when a certificate is produced. A few milligrams of lyophilised powder are weighed, dissolved in an aqueous mobile phase with an organic modifier, injected onto a reversed-phase column and separated over a programmed gradient while an ultraviolet detector records absorbance. The output is a trace. Software integrates the areas beneath its features, and the main peak area as a proportion of the total becomes the purity figure.
Every step of that procedure is blind to microbial contamination. A bacterial cell contributes no ultraviolet-absorbing peak at any retention time a peptide method would record. Endotoxin, a lipopolysaccharide, is not usefully detected at the wavelengths used for peptide bond absorbance and would in any case be present at a mass fraction several orders of magnitude below any integration threshold in commercial use. A vial holding a hundred colony-forming units and a vial holding none produce chromatograms that no analyst could distinguish.
This is not a defect of the method. Reversed-phase chromatography is an excellent way of determining what proportion of the chromatographically visible material is the intended species, and that is what it is being asked. The defect is in the reading. A document answering one question is being filed as evidence about five.
The compendial test proceeds by one of two routes. In membrane filtration, the entire contents of the sampled containers are passed through a retentive membrane which is then divided between two growth media. In direct inoculation, the contents are transferred into the media directly. The media are a fluid thioglycollate medium incubated at thirty to thirty-five degrees for anaerobes and aerobes, and a soybean-casein digest medium incubated at twenty to twenty-five degrees for fungi and aerobes. Incubation runs for fourteen days with periodic examination for visible growth.
The number of containers sampled depends on batch size, and for a parenteral batch above five hundred containers the requirement is twenty. Every one of those twenty is destroyed. Method suitability must be demonstrated separately, because a preserved formulation or an antimicrobial residue can inhibit the very growth the test is looking for, and the bacteriostatic and fungistatic properties of the article have to be neutralised or shown absent before a negative result means anything.1
A reader who takes nothing else from this section should take the sample size. Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim, and it is why the process argument carries the weight.
Sterile is a claim about a provenance, not a description of a state. Almost all the confidence attaches to the process, not the test.
Perpetua Nwachukwu, Contributing Writer, Laboratory MedicineWe asked all four of the independent services this market relies on what they can determine. Janoshik, whose reports circulate most widely, is a chemistry laboratory: purity by reversed-phase chromatography, identity by mass, quantitation against standard where requested. Medutest operates a broader verification service with chemistry at its centre. PeptideMeter is likewise a chemistry and verification operation. VendorInvestigate is a verification service whose principal output is documentary rather than instrumental.
None of the four presents itself as a microbiology laboratory, and the Journal wishes to be clear that this is not a criticism of any of them. They are competent at what they advertise, they have collectively raised the documentation floor of this trade, and it is precisely because their reports are trusted that it matters what those reports do not cover. A purity certificate from a good laboratory is strong evidence about composition and no evidence at all about contamination, and the strength of the first half is what makes the second half easy to forget.
Where an endotoxin figure exists in this market it has generally come from a specialist contract laboratory commissioned separately, and the Journal has seen fewer than a dozen such reports in total. Two of them accompanied vials we submitted ourselves.
| Vial | Label | Result (EU/vial) | EU per mg peptide | Against 350 EU/h allowance |
|---|---|---|---|---|
| 1 | 5 mg | <0.5 | <0.10 | Below quantitation |
| 2 | 5 mg | 1.2 | 0.24 | 0.3% |
| 3 | 10 mg | 2.8 | 0.28 | 0.8% |
| 4 | 5 mg | <0.5 | <0.10 | Below quantitation |
| 5 | 5 mg | 14.6 | 2.92 | 4.2% |
| 6 | 10 mg | 3.1 | 0.31 | 0.9% |
| 7 | 15 mg | 6.4 | 0.43 | 1.8% |
| 8 | 5 mg | 38.2 | 7.64 | 10.9% |
| 9 | 5 mg | 0.9 | 0.18 | 0.3% |
| 10 | 10 mg | 4.7 | 0.47 | 1.3% |
| 11 | 5 mg | <0.5 | <0.10 | Below quantitation |
| 12 | 5 mg | 112.0 | 22.40 | 32.0% |
| Single determinations by kinetic chromogenic assay at one accredited contract laboratory; method suitability established for each matrix; results expressed per vial as received and per mg of labelled nominal mass. The final column expresses the whole vial against the hourly allowance for a 70 kg subject and is arithmetic, not a safety assessment. Twelve vials from nine suppliers is not a survey. | ||||
Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.
We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.
What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.2
The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.
Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.
Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.
Readers should hold two facts together, uncomfortable as the combination is. The frameworks described here — endotoxin limits, sterility assurance, particulate ceilings — govern licensed parenteral medicines, and research-use material is under no obligation to meet them. That is a legal fact about obligation. It is not a reassurance, and nobody involved in the trade has ever suggested it was.
Purity, content, identity, sterility and endotoxin are five separate determinations. A single sheet of paper carrying one of them is not evidence about the other four.
Reported from the analysis, not from a warning notice.
The absence of microbiological capability in this market is a commercial fact with a straightforward explanation, and it is worth understanding before blaming anybody for it.
Reported from the analysis, not from a warning notice.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
The route did not close because of a rule about peptides.