Sterility is not a percentage, which is the whole difficulty

Purity, content, identity, sterility and endotoxin are five separate determinations. A single sheet of paper carrying one of them is not evidence about the other four.

A certificate of analysis for a research peptide is, in the overwhelming majority of cases, a document about chemistry. It reports a chromatographic purity figure, sometimes a mass, occasionally a water content, and it is generated from a few milligrams of powder dissolved in a vial of mobile phase. Nothing in that procedure has any bearing on whether the sealed container it came from holds viable microorganisms, whether the powder carries pyrogenic material from an upstream water system, or whether the stopper has maintained a seal since the day it was crimped. The document is accurate and it is answering a different question.

Two questions that share a piece of paper

Consider what happens physically when a certificate is produced. A few milligrams of lyophilised powder are weighed, dissolved in an aqueous mobile phase with an organic modifier, injected onto a reversed-phase column and separated over a programmed gradient while an ultraviolet detector records absorbance. The output is a trace. Software integrates the areas beneath its features, and the main peak area as a proportion of the total becomes the purity figure.

Every step of that procedure is blind to microbial contamination. A bacterial cell contributes no ultraviolet-absorbing peak at any retention time a peptide method would record. Endotoxin, a lipopolysaccharide, is not usefully detected at the wavelengths used for peptide bond absorbance and would in any case be present at a mass fraction several orders of magnitude below any integration threshold in commercial use. A vial holding a hundred colony-forming units and a vial holding none produce chromatograms that no analyst could distinguish.

This is not a defect of the method. Reversed-phase chromatography is an excellent way of determining what proportion of the chromatographically visible material is the intended species, and that is what it is being asked. The defect is in the reading. A document answering one question is being filed as evidence about five.

The filter, and the test that proves it survived

Sterilising-grade filtration through a membrane of 0.22 micron nominal rating is the operation on which aseptic processing rests. The membrane is qualified by challenge with a small bacterium at high concentration under the process conditions, and a filter that permits no passage under that challenge is accepted as sterilising for that fluid.

The critical practice is not the filtration but the integrity test that follows it. A membrane can be damaged during installation, during sterilisation, or by pressure excursions in use, and a damaged membrane looks exactly like an intact one. Bubble point, diffusive flow and pressure hold tests each detect a breach by measuring gas behaviour across a wetted membrane, and a post-use test is the only evidence that the filter was intact while the product was passing through it. A pre-use test alone establishes nothing about the state of the membrane at the end of the run.

This is the question the Journal has found most useful when assessing whether a fill operation is a real one. It is specific, it has a yes or no answer, the answer is recorded in the batch documentation as a matter of course, and it cannot be answered plausibly by anybody who is not actually running the process.

Killing the bacteria does not remove the endotoxin, and may increase the free concentration.

The statistics, worked in one paragraph

Suppose a batch of ten thousand vials in which one vial in a thousand is contaminated — a rate that would be a serious finding in any regulated operation and is invisible to any buyer. The probability that a single randomly chosen vial is clean is 0.999. The probability that all twenty sampled vials are clean is 0.999 raised to the twentieth power, which is approximately 0.980. The sterility test therefore passes this batch about ninety-eight times in a hundred.

Push the contamination rate up tenfold, to one vial in a hundred, and the test still passes the batch roughly eighty-two times in a hundred. To reach an even chance of detection at a one per cent contamination rate you would need to sample about seventy containers; to have a reasonable prospect of catching a one-in-a-thousand rate you would need to sample several hundred, which for most batches means testing a substantial fraction of the product.

This is not a criticism of the compendial test, which is designed as a final check against gross failure and performs that function. It is the reason no serious manufacturer treats a passed sterility test as the basis of the sterility claim, and the reason that a research supplier offering to have a vial sterility-tested on request is offering something considerably weaker than it sounds.

Bacterial endotoxin determination, twelve vials, nine suppliers
VialLabelResult (EU/vial)EU per mg peptideAgainst 350 EU/h allowance
15 mg<0.5<0.10Below quantitation
25 mg1.20.240.3%
310 mg2.80.280.8%
45 mg<0.5<0.10Below quantitation
55 mg14.62.924.2%
610 mg3.10.310.9%
715 mg6.40.431.8%
85 mg38.27.6410.9%
95 mg0.90.180.3%
1010 mg4.70.471.3%
115 mg<0.5<0.10Below quantitation
125 mg112.022.4032.0%
Single determinations by kinetic chromogenic assay at one accredited contract laboratory; method suitability established for each matrix; results expressed per vial as received and per mg of labelled nominal mass. The final column expresses the whole vial against the hourly allowance for a 70 kg subject and is arithmetic, not a safety assessment. Twelve vials from nine suppliers is not a survey.

Three method families, and what each returns

The gel-clot method is the oldest and simplest: lysate is combined with the sample, incubated, and the tube inverted. A firm clot that does not slip is a positive. It is a limit test, and by testing serial dilutions it becomes semi-quantitative. Its virtues are robustness and independence from instrumentation; its limitation is resolution.

Turbidimetric methods read the increasing turbidity produced by clotting protein formation, either as an endpoint at fixed time or kinetically as the time to reach a defined turbidity. Chromogenic methods substitute a synthetic peptide substrate that releases a chromophore when cleaved by the activated enzyme, and read absorbance. The kinetic chromogenic variant — measuring the time to a defined absorbance change against a standard curve — is the method of record for most modern release testing, offering quantitation across several orders of magnitude from a small sample volume.

All three are compendial, all three require a demonstration that the sample matrix neither inhibits nor enhances the reaction, and all three are calibrated against an international reference endotoxin rather than against a mass. A result reported without the method and without the inhibition-enhancement result is, once again, a number without a procedure.1

The endotoxin limit, calculated

The limit is derived, not looked up. For a parenteral product other than an intrathecal one, the threshold pyrogenic dose is taken as five endotoxin units per kilogram of body weight per hour. The endotoxin limit for the product is that figure divided by the maximum dose per kilogram administered within an hour. For an intrathecal route the threshold falls to 0.2 endotoxin units per kilogram, a twenty-five-fold reduction that reflects the absence of the systemic buffering the bloodstream provides.

Work it for a concrete case. A seventy-kilogram subject has an hourly allowance of three hundred and fifty endotoxin units. A vial nominally containing five milligrams of peptide, reconstituted to two millilitres, from which a fifth of a millilitre is drawn, delivers a tenth of the vial contents. If the whole vial carried three hundred and fifty endotoxin units, that draw would deliver thirty-five — a tenth of the allowance. The limit expressed per milligram of peptide is what a certificate should carry, because it is the only form of the number that survives a change in reconstitution volume.

None of the arithmetic is difficult. What is missing from this trade is not the calculation but the measured numerator.2

1128456280100Purity45Identity20Water10Content5Endotoxin0Sterilityper cent of companies
Figure. Proportion of the twenty tracked companies whose standard certificate reports each determination. Purity is universal; the microbiological attributes are absent rather than reported negative.

What the cake tells you

A lyophilised plug is a physical record of the cycle that produced it. A well-formed cake occupies close to the volume of the solution that was frozen, has a matte, uniform appearance, retains a defined edge where it met the glass, and dissolves rapidly and completely on addition of diluent. That appearance indicates that the product was frozen below its critical formulation temperature and dried without the structure collapsing.

Departures are informative. A shrunken, translucent or glassy plug suggests collapse during primary drying — the ice sublimed faster than the amorphous matrix could hold its structure — which is associated with higher residual moisture and a shorter shelf life. A cake that has partly detached and moves freely suggests mechanical handling after drying, which is cosmetic. A cake showing melt-back at the base, or a visible meniscus line, suggests a shelf temperature excursion. Slow or incomplete reconstitution suggests either collapse or an unfavourable surface.

None of these observations is a purity finding, a sterility finding or an endotoxin finding, and it is important not to overclaim. What they are is the only direct evidence about process control that arrives in the box, and reading them costs nothing. The Journal photographs every cake it receives before opening the vial, for exactly that reason.3

What we submitted, and what came back

Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.

We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.

What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.4

The four services have raised the documentation floor of this trade. That is exactly why it matters what their reports do not cover.

Nikolaj Brandvold, Contributing Writer, Sterility

Documentation practice, named and criticised

The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.

Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.

What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.

Container closure integrity methods, by philosophy
MethodClassNon-destructiveApproximate defect resolution
Dye ingress under vacuumProbabilisticNo10–20 µm, poorly characterised
Microbial immersion challengeProbabilisticNo5–10 µm, highly variable
Vacuum decayDeterministicYes2–5 µm
High-voltage leak detectionDeterministicYes1–5 µm, liquid fills
Laser headspace analysisDeterministicYesSub-micron, stability-programme capable
Helium mass spectrometryDeterministicYesSub-micron
Resolution figures are indicative and package-dependent; the meaningful specification for any given system is its maximum allowable leakage limit, established experimentally rather than assumed.

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

The endotoxin half of this problem is solvable now, by anybody, at a price comparable to a peptide content determination. That is the single most practically useful sentence in this article. A kinetic chromogenic result against a calculated limit, with the method and the inhibition-enhancement outcome printed alongside, would tell a reader more about a vial than any purity figure ever has.

References

  1. United States Pharmacopeia. General Chapter ⟨85⟩ Bacterial Endotoxins Test. USP–NF, Rockville, MD.
  2. European Pharmacopoeia. Chapter 5.1.10 — Guidelines for Using the Test for Bacterial Endotoxins. Council of Europe, Strasbourg.
  3. “Cake appearance, collapse temperature and residual moisture in lyophilised peptide formulations.” AAPS PharmSciTech. 2019;20(7):286.
  4. International Organization for Standardization. ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories. Geneva, 2017.

Letters to the Editor

3 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

You write that recombinant factor C is insensitive to the glucan branch of the cascade. It would be worth adding why anybody cares: cellulose filter media and certain paper wrappings shed glucans, and a laboratory that has chased a false positive through three repeat assays will never willingly go back to a reagent that responds to them.

E. Marchbank, Perth, WA

Your endotoxin table gives vial 12 at 112 EU per vial and then declines to say whether that is dangerous. I understand why. It is still frustrating to read a figure of that size next to the sentence "arithmetic, not a safety assessment".

J. Prendergast, Wollongong, NSW

The Journal replies

We understand the frustration and we are going to keep doing it. The figure sits at roughly a third of the hourly systemic allowance for a 70 kg adult if the whole vial were administered at once, which is a comparison a reader can make. What we cannot do is turn a single determination on one vial into a statement about a person, and pretending otherwise would be the more serious failure.

I have worked in aseptic fill for nineteen years and your section on media fills understates one thing. The scale is not the hard part. Running the simulation with every intervention the real process contains — every stopper jam, every environmental sample, every gowning break — is the hard part, and a simulation that omits the interventions is theatre with a growth medium in it.

B. Sundqvist, Turku

The Journal replies

That is a better statement of the point than ours and we have amended the section to make the interventions explicit. The scale figure without the intervention requirement is exactly the sort of number that gets quoted as reassurance.