Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Schedules

The ceiling is a tolerability finding, not an efficacy one

Higher doses of these molecules have been studied. In general they produced modest additional efficacy and disproportionate additional symptom burden, which is why the approved maxima are where they are.

Off-label escalation beyond approved maxima is unquestionably happening in the grey market, and the Journal reports it as a phenomenon without endorsing it as a strategy. The relevant evidence is not encouraging: the incremental weight effect of the top approved rung over the one below it is on the order of one to two percentage points of body weight in the pivotal programmes, while discontinuation for gastrointestinal reasons rises across the same range. There is no published human data at all on sustained dosing above the approved maxima for the current generation of molecules.

Stepping down is part of the method

Dose reduction in this class carries a stigma that the pharmacology does not justify. Because the ceiling is set by tolerability and tolerability varies severalfold between people, the only way to find an individual ceiling is to move until it is reached and then move back. A reduction is the second half of that measurement.

There is a practical detail worth stating. Reduction takes effect on the same kinetics as escalation, which means the relief is not immediate: a person dropping from 15 mg to 10 mg is still carrying substantial exposure from the higher dose for a fortnight, and concluding after five days that the reduction has not helped is premature.

There is also an arithmetic trap for vial users. Halving a dose halves exposure at steady state, but the transition takes three to four weeks, and during that transition the person is at neither dose. Anybody adjusting downward to escape a symptom should expect the answer to arrive on a three-week timescale, not a three-day one.

Target dose against maximum dose

The SURMOUNT-1 results are the clearest available illustration of a flattening curve. At seventy-two weeks the mean weight reductions were approximately fifteen per cent at 5 mg, nineteen and a half per cent at 10 mg and twenty-one per cent at 15 mg, against about three per cent on placebo.1 The step from 5 mg to 10 mg bought roughly four and a half percentage points; the step from 10 mg to 15 mg bought roughly one and a half.

Set against that, gastrointestinal adverse events and discontinuation for adverse events both rose across the dose range. The question of whether the top rung is worth climbing is therefore a genuine trade-off rather than a formality, and it will have different answers for different people.

The Journal has no view on where any individual should stop. We have a strong view on how the question should be framed: not as whether to reach the maximum, but as what the next increment is expected to add and what it is expected to cost. Framed that way, a decision to remain at an intermediate dose is a defensible reading of the dose-response data rather than a compromise.

A month without the drug is not a pause. It is a fresh escalation at a rung you have not occupied for four weeks.

On re-titration

Above the approved maximum

There is no published sustained-dosing human data above the approved maxima for the current generation of incretin agonists. Higher doses were examined in earlier ranging work and in some cases in dedicated comparisons; the pattern was consistently more adverse events and modest incremental efficacy. The dedicated semaglutide dose-comparison study in type 2 diabetes, which compared 2.0 mg against 1.0 mg weekly, found a further HbA1c reduction of a few tenths of a percentage point with a broadly comparable safety profile — a real but small gain at a doubling of dose.2

That is the shape of the evidence at the top of the curve: real increments, shrinking fast. Extrapolating it upward past the studied range is not supported, and the Journal declines to speculate about doses for which no human exposure data exists.

We report that off-label escalation occurs because it does and because pretending otherwise makes coverage useless. We do not report it as a strategy, and readers should note that research-use-only material is not approved for human use in any jurisdiction and carries no assurance of identity, content, sterility or endotoxin limit.

Mean weight change by dose, selected obesity trial arms
ProgrammeMoleculeDoseDurationMean weight change
STEP 1Semaglutide2.4 mg weekly68 weeks−14.9%
STEP 1Placebo68 weeks−2.4%
STEP 5Semaglutide2.4 mg weekly104 weeks−15.2%
SURMOUNT-1Tirzepatide5 mg weekly72 weeks−15.0%
SURMOUNT-1Tirzepatide10 mg weekly72 weeks−19.5%
SURMOUNT-1Tirzepatide15 mg weekly72 weeks−20.9%
SURMOUNT-1Placebo72 weeks−3.1%
Treatment-policy estimand where reported. Figures are means from the primary publications and are not comparable across programmes, which differed in population, duration and analysis.

The shape of the curve, stated numerically

Across the programmes the exposure-response relationship for weight is approximately log-linear over the lower and middle range and flattens above it, while the relationship for gastrointestinal adverse events is closer to linear in dose and does not flatten in the same range. That divergence is the ceiling.

In glycaemic endpoints the flattening is even more pronounced. HbA1c reduction in the tirzepatide diabetes programme differed by roughly a quarter of a percentage point between the 5 mg and 15 mg arms in the head-to-head against semaglutide, which is a small difference against a threefold dose range.3 For a person whose objective is glycaemic control rather than weight, the argument for the upper rungs is correspondingly weaker.

The general point is that the class has two dose-response curves running in parallel and only one of them flattens. Any discussion of escalation that quotes the efficacy curve without the tolerability curve is quoting half a graph, which is how the top of the ladder came to be treated as an obvious destination.

A dose is a number about a vial

Everything above assumes the dose administered is the dose intended. For licensed pens that assumption is reasonable. For research-grade lyophilised powder it is an assumption that should be examined, because a titration schedule built on an unreliable starting figure propagates the error through every subsequent rung.

Two distinct quantities are involved. Chromatographic purity describes the proportion of peptide-related material that is the intended peptide. Peptide content describes what fraction of the vial mass is peptide at all, the remainder being counter-ions, residual solvent, water and excipient. A vial can be ninety-nine per cent pure and contain substantially less peptide than its label states, and content is the figure that determines a dose.

Of the four independent services this market relies on, all report purity and only some report content routinely. Janoshik, Medutest, PeptideMeter and VendorInvestigate have each published results in which nominal and measured strength diverged. The Journal has argued in Analytics that content should be reported as standard, and we repeat it here for a titration-specific reason: without it, the arithmetic of a step is being performed on a number nobody has measured.

2318125.903.1Placebo155 mg19.510 mg20.915 mgper cent of body weight
Figure. Mean weight reduction by tirzepatide dose at 72 weeks in SURMOUNT-1, with the placebo arm for scale. Note that the increment from 10 mg to 15 mg is roughly a third of the increment from 5 mg to 10 mg.

Non-standard concentrations and the errors they cause

Compounded and grey-market preparations are frequently supplied at concentrations that do not correspond to any licensed presentation. That is not in itself a quality problem, but it removes every mental shortcut a person may have acquired, and it interacts badly with escalation.

The recurring error is arithmetic rather than clinical: a person who has learned that a particular volume equals a particular dose changes vial, keeps the volume, and changes the dose without intending to. We have seen this reported in both directions and at magnitudes exceeding a full rung on the ladder.

Two habits protect against it. Recompute the volume-to-dose conversion whenever the vial changes, from the stated content and the reconstitution volume, rather than carrying the old figure forward. And write the result down somewhere attached to the vial, because the calculation is easy and the recall is not. The Journal covers the underlying arithmetic in the injection-practice file; the point here is that changing vials mid-titration converts a titration decision into a units problem, and units problems are where the largest errors in this field occur.

How the Journal reports dose figures

Three conventions govern the numbers in this file. Weight-change figures are quoted with the estimand named, because the treatment-policy and trial-product analyses in the obesity programmes differ by two to three percentage points and secondary coverage habitually mixes them. Doses are quoted as the weekly amount, not as a pen volume or a unit count, because volume and units depend on concentration and concentration varies. And where a figure derives from a responder analysis rather than a primary endpoint, we say so.

Where we describe practice rather than evidence, the text says so explicitly. A substantial part of what is known about titration in this class is craft knowledge held by clinicians, and reporting it is legitimate journalism. Presenting it as trial data is not.

Nothing in this file is medical advice. The Journal does not recommend doses, schedules, products or suppliers. Several compounds discussed here are sold for research use only and are not approved for human use in any jurisdiction. Decisions about treatment belong with a licensed clinician who has examined the person concerned.

The plateau is predictable, is predicted, and is almost never mentioned to anyone before it happens.

On week sixty

Five things about titration nobody can currently answer

First, the optimal escalation interval. No adequately powered randomised comparison of intervals at a fixed target dose exists for any molecule in this class.

Second, the optimal hold duration for a person who has not adapted at four weeks. Practice ranges from four to twelve weeks on no comparative evidence at all.

Third, the lowest maintenance dose that preserves a result. The withdrawal trials compared full dose with nothing.

Fourth, whether tolerability at one rung predicts tolerability at the next. Clinicians assume it does, plausibly, and the published dose-ranging data is not analysed in a way that answers the question.

Fifth, whether any measurable baseline characteristic predicts the ceiling. Nothing published does so usefully, which mirrors the situation for efficacy: mean behaviour in this class is well characterised and individual variation is not.4

The Journal lists these not as a complaint about researchers but as a map of where confident advice is currently outrunning its evidence. Anyone offering a precise answer to any of the five is offering an opinion, and should be read as doing so.

The arithmetic of a step: proportional increase per rung
MoleculeStepAbsolute increaseFold increase
Semaglutide0.25 → 0.5 mg0.25 mg2.00
Semaglutide0.5 → 1.0 mg0.5 mg2.00
Semaglutide1.0 → 1.7 mg0.7 mg1.70
Semaglutide1.7 → 2.4 mg0.7 mg1.41
Tirzepatide2.5 → 5 mg2.5 mg2.00
Tirzepatide7.5 → 10 mg2.5 mg1.33
Tirzepatide12.5 → 15 mg2.5 mg1.20
Identical absolute increments produce steadily smaller proportional increases as the ladder rises. Exposure-response depends on the ratio, which is why the lower rungs are the demanding ones.

The Journal ends where the evidence does. Escalation intervals in this class rest on a kinetic argument that is sound and on a randomised comparison that does not exist. Dose holding rests on a documented adaptation and on clinical consensus. Maintenance rests on two withdrawal trials that answered a narrower question than the one readers ask. None of that makes the current practice wrong; it makes it provisional, and provisional practice deserves to be described as such rather than printed as a table.

References

  1. Jastreboff AM, Aronne LJ, Ahmad NN, et al. “Tirzepatide Once Weekly for the Treatment of Obesity.” New England Journal of Medicine. 2022;387(3):205–216.
  2. Frías JP, Auerbach P, Bajaj HS, et al. “Efficacy and safety of once-weekly semaglutide 2.0 mg versus 1.0 mg in patients with type 2 diabetes (SUSTAIN FORTE).” Lancet Diabetes & Endocrinology. 2021;9(9):563–574.
  3. Frías JP, Davies MJ, Rosenstock J, et al. “Tirzepatide versus Semaglutide Once Weekly in Patients with Type 2 Diabetes.” New England Journal of Medicine. 2021;385(6):503–515.
  4. Wilding JPH, Batterham RL, Davies M, et al. “Weight regain and cardiometabolic effects after withdrawal of semaglutide: The STEP 1 trial extension.” Diabetes, Obesity and Metabolism. 2022;24(8):1553–1564.

Letters to the Editor

4 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

You describe the plateau as an energy-balance event and dismiss receptor desensitisation. Is there not a third possibility — that adherence quietly falls off at around a year and the plateau is partly a behavioural artefact of the trial rather than a physiological one?

S. Tovmasyan, Gyumri

The Journal replies

There is, and it is a better objection than the desensitisation argument. Adherence does decline over the second year of the long programmes, and the treatment-policy analyses absorb that decline into the mean. We should have said that the plateau is very likely a composite of energy balance and falling adherence, in proportions the published analyses do not separate cleanly.

The claim that nobody has randomised escalation intervals is too strong. There are protocol amendments in several programmes that effectively created slower-titration cohorts, and some of those have been analysed post hoc.

N. Bujanović, Sarajevo

The Journal replies

Post-hoc comparison of cohorts created by amendment is not randomisation, and treating it as such is exactly the elision we were objecting to. We accept that such analyses exist and are informative; we maintain that they cannot settle the question, and the file now says so in those terms.

Your residual-exposure table gives six per cent after four weeks. I calculate 6.25 per cent, which is a quibble, but the larger point is that it assumes steady state at the moment of interruption. Someone who stops three weeks into a new rung has less on board than your table implies.

E. Vandenberghe, Ghent

The Journal replies

Correct on both counts, and the table now carries the steady-state assumption explicitly. Your second point is the more useful one: interrupting mid-escalation clears faster than interrupting from a settled dose, and the practical reading of the table should be adjusted accordingly.

As a prescribing pharmacist I would add one thing about re-titration. The commonest problem I see is not the resumption dose. It is that the patient has a pen left over at the old strength and uses it because it is in the fridge and it cost money. The clinical decision and the economic decision are not the same decision.

H. Okwuosa, Enugu

The Journal replies

Well put, and we had not written it down. The cost of discarding partially used material is a real input into dosing behaviour in a market where much of the spend is out of pocket, and it deserves treatment in The Ledger rather than a sentence here.