A supplier suspends shipping to Portugal after 17 consecutive customs detentions
The route did not close because of a rule about peptides.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Documents
The purity figure is the least informative line on a well-constructed certificate and the only line most buyers read.
A certificate of analysis is not a test result. It is a statement, made by whoever signs it, that a defined quantity of material identified by a batch number was subjected to defined tests by defined methods and produced results within defined limits on a defined date. Every element of that sentence is load-bearing, and a document missing any of them is not a weak certificate but a different kind of object: an assertion of quality with no way back to the evidence. The Journal has read several hundred of these and the distribution is not encouraging, though the reason is more mundane than the trade’s more excitable commentary suggests.
The confusion at the root of almost every dispute about certificates is a category error. A certificate of analysis is not a measurement. It is a record asserting that measurements were made, by named methods, on identified material, on a stated date, with stated outcomes, and that somebody reviewed and released the batch on that basis. The measurements exist elsewhere: in instrument data files, in analyst notebooks, in a laboratory information system. The certificate is the summary that travels with the goods.
This distinction has a practical consequence. When the Journal wants to know whether a purity figure is sound, we do not scrutinise the certificate; we ask for the underlying laboratory report and, where possible, the chromatogram. The certificate can only tell us what somebody concluded. The chromatogram tells us what the instrument saw, and the two are separated by decisions about integration, thresholds and reporting that the certificate does not record.
It follows that a certificate’s value is almost entirely a function of whether it can be traced back to that underlying evidence. A document with a batch number, a date, a named method and a named analyst is checkable in principle even if nobody ever checks it. A document with a percentage and a logo is not checkable by anyone, including the company that issued it, and the difference between those two situations is invisible to a buyer who reads only the number.
The top of a certificate answers the question, what is this document about. A complete header names the product, gives a catalogue or item number, gives the batch or lot number, states the quantity or fill weight, names the manufacturer and the site, and identifies the customer or order where applicable. Some add a chemical name, a sequence in single-letter code, a molecular formula and a molecular weight, all of which are useful because they let a reader check the theoretical values used elsewhere on the page.
The sequence in particular is worth insisting on. A certificate that prints the one-letter sequence has given a reader the means to calculate the expected mass independently, and therefore to check the identity line. Two of the twenty companies in the Journal’s dossier programme do this as standard. It costs nothing and it converts one line of the document from an assertion into a verifiable claim.
What a header should never do is identify the product only by a trade name. A vial described as a proprietary blend with no chemical identity, no formula and no sequence cannot be checked against anything, and a certificate for such a product is a document about a name. This is a documentary observation rather than an accusation, and the remedy is trivial: print the sequence.
A purity limit of ≥95% on material that always reports 99% is not a control. It is a formality with a number attached.
On decorative acceptance criteriaThe body of a certificate is a table, and a complete one has four columns: the test performed, the method used, the specification applied, and the result obtained. Four columns, one row per test. That structure is not a convention peculiar to pharmaceuticals; it is what a record of controlled testing looks like in any field, because each column answers a question the other three cannot.
The method column is where the detail belongs — not the word HPLC but a method identifier, a gradient, a wavelength, a column chemistry. The specification column states what the batch had to achieve. The result column states what it did. A certificate carrying only test and result has dropped the two columns that make the result interpretable, and this is by far the commonest structural deficiency the Journal encounters.
The compendial framework for validating an analytical procedure exists precisely to establish that a stated method can discriminate what it claims to discriminate, which is why a method reference is not bureaucratic ornament but the hook on which everything else hangs.12 A named method can be looked up, compared, criticised and repeated. An unnamed one cannot be, and a result generated by one is a number whose provenance stops at the page.
| Interval | Certificates | Share |
|---|---|---|
| Within 14 days | 31 | 49% |
| 15–60 days | 12 | 19% |
| 61–180 days | 5 | 8% |
| Over 180 days | 2 | 3% |
| One or both dates absent | 13 | 21% |
| Where only one date was present the certificate is counted in the final row. The median interval among the fifty documents carrying both dates was eleven days, which is unremarkable and reassuring; the more consequential interval — between the date of analysis and the date the buyer receives the vial — is not recorded on any certificate the Journal has seen. | ||
Near the top of most test tables sit two entries that buyers skip and chemists do not: appearance and solubility. Appearance is reported as something like “white to off-white lyophilised powder”, and it is a real test with real discriminating power. A peptide cake that is yellow, or grey, or that has collapsed into a glassy plug rather than a light lyophilised mass, is telling you something about the drying cycle, about oxidation, or about a temperature excursion in transit.
Solubility is similarly underrated. A specification reading “clear, colourless solution on reconstitution in water at 1 mg/mL” establishes that the material dissolves at the concentration a user will need, without haze, and haze on reconstitution is a genuine finding: it can indicate aggregation, incomplete removal of a protecting group, or particulate contamination. It is also the only test on most certificates that a buyer can repeat at home.
The reason to press on these lines is that they are cheap, they are already on the form, and they degrade in a way the purity figure does not capture. A certificate reporting a white powder for material that arrives faintly yellow has not been falsified. It has been overtaken by events, which is exactly what a certificate with an eleven-month-old date of analysis should be expected to be.
Minute one: find the batch number on the certificate and find it on the vial. Not the carton. If they do not match, or the vial has no number, stop and ask the supplier what the relationship is. Minutes two and three: find the date of manufacture and the date of analysis, and compute the interval. Then compute the interval between the date of analysis and today.
Minutes four and five: read the test table and count the columns. If the specification column is missing, the results cannot be assessed. If the method column is missing or says only HPLC, the purity figure cannot be compared with anybody else’s. Minute six: check the identity line for a theoretical mass, and check whether the convention — monoisotopic or average — is stated. Minute seven: read the signature block for a name and a role.
Minutes eight to ten: list what is not there. Content, water, counter-ion, residual solvent, endotoxin, sterility. Then decide whether any of those matter for what you are doing, which is a question only the reader can answer. The exercise does not establish that a certificate is right or wrong. It establishes whether the document can be checked at all, and in the Journal’s experience roughly a third of certificates in general circulation fail before minute five. Readers who work through this and find something they cannot interpret are welcome to write to standards@compoundjournal.com.
What remains genuinely absent from this market is any documentation of what happens to a vial between the date of analysis and the day it is opened. Every certificate is a snapshot at manufacture; nothing records the four months in transit and storage that follow. Until somebody prices a cheap release-and-receipt check, the honest statement about any research vial is that its purity was measured once, some time ago, by a method that may not be stated.
The route did not close because of a rule about peptides.
Parts per million sound impressive until they are converted into daltons at the molecular weight of the thing being measured.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
The supplier has not disputed the finding. It has not explained the gap either.
Two signatures — one who performed the work, one who approved its release — are the ordinary regulated convention and are almost unknown here.