Twenty-eight days is a number from somebody else’s product

Every degradation pathway accelerates by orders of magnitude on reconstitution, because the solvent that lyophilisation removed is the reagent most of them need.

Reconstitution is the point at which a stable product becomes a perishable one, and the change is not incremental. Deamidation, hydrolysis and disulphide exchange all require water as a participant or a medium; aggregation requires molecular mobility that the dried matrix denies. Adding two millilitres of diluent restores all of it at once. The consequence is that a product with a two-year shelf life as a cake may have an in-use period measured in weeks, and the second figure is not derivable from the first by any calculation.

A shelf life is a claim about a condition

Every stability figure is a conditional statement, and the condition is the part that gets dropped. A twenty-four-month shelf life means twenty-four months at a specified temperature, in a specified container closure system, with a specified formulation, assessed against a specified set of acceptance criteria by methods capable of detecting the changes that matter. Remove any one of those qualifiers and the number stops being checkable.

The trade routinely reports the number and none of the qualifiers. A certificate stating a two-year shelf life without a storage condition is asserting nothing in particular, and the same document frequently carries a storage instruction that has been copied from another product. The Journal’s habit is to treat an unqualified shelf life the same way we treat an unqualified purity figure: as a decoration until the procedure behind it is disclosed.

There is also a vocabulary problem worth clearing up. An expiry date states that material should not be used beyond it. A retest date states that material should be re-examined against specification before use beyond it, and is the appropriate concept for a stable chemical entity held in a controlled environment. Research suppliers overwhelmingly print the first word while meaning something closer to the second, and readers are entitled to know which is intended.1

What a logger records, and what it cannot

A single-use electronic logger is a thermistor, a clock, a small memory and a battery, and its output is a series of readings of the air adjacent to its housing at a configured interval. Four configuration choices determine what it can detect. The sampling interval sets the shortest excursion it can see: a device sampling every fifteen minutes will record a ten-minute spike only by luck. The memory depth sets the maximum journey length before it stops or overwrites. The start delay determines whether the packing operation appears in the trace. And the calibration interval determines whether the numbers mean anything at all.

Placement matters more than any of them. A logger in the outer carton records the transport environment; a logger inside the insulated payload against the vials records something much closer to what the product experienced; and the two can differ by twenty degrees during the same afternoon. A trace without a stated placement is close to uninterpretable, and placement is almost never stated.

Our own nine shipments used devices calibrated within the preceding twelve months, sampling at five-minute intervals, placed inside the insulated payload adjacent to the vials, started at the point of packing where we controlled it and at the point of receipt of the outbound label where we did not. We state all of that because a trace is a measurement and a measurement without its method is decoration.2

The aggregate arrives at the column, comes apart, and is recorded as monomer.

Callum Brathwaite, Analytical Chemistry Correspondent

In-use stability, and where the numbers come from

In-use stability is established by a dedicated study: the finished product reconstituted as intended, at the intended concentration, in the intended container, stored at the intended temperature, sampled at intervals, and analysed by stability-indicating methods for related substances and by a size-based method for aggregates. The output is a period, and the period belongs to that formulation in that container and to nothing else.

The in-use periods circulating in this market are not derived that way. They are, in the Journal’s experience of tracing them, borrowed from the labelling of marketed pen presentations, which are different formulations at different concentrations with different preservative systems in different primary containers. Marketed in-use periods for the incretin pens run from four weeks to eight depending on product and storage condition, and none of those figures transfers to a reconstituted research vial by any argument we can construct.

What can be said generally is directional rather than numerical. Degradation in solution proceeds orders of magnitude faster than in the cake. Lower temperature helps substantially. Repeated warming and cooling of an opened vial is worse than steady storage. Preservative-containing diluent addresses microbial growth and does nothing about chemical degradation. And in the absence of a study on the actual product, any specific number quoted for an in-use period is an assumption wearing a specification’s clothes.

One further loss is routinely mistaken for degradation. Peptides adsorb to glass and polymer surfaces, and the relationship runs the awkward way: the more dilute the solution, the larger the proportion a given surface area removes.3

Storage and testing conditions used in a registration stability programme
Intended storageLong-term conditionIntermediateAccelerated
Room temperature25 °C / 60% RH, ≥12 months30 °C / 65% RH40 °C / 75% RH, 6 months
Room temperature, hot climatic zone30 °C / 65% RH, ≥12 monthsnot applicable40 °C / 75% RH, 6 months
Refrigerated5 °C ± 3 °C, ≥12 monthsnot applicable25 °C / 60% RH, 6 months
Frozen−20 °C ± 5 °C, ≥12 monthsnot applicablesingle-batch excursion study
Below −20 °Ccase by casenot applicablesingle-batch excursion study
Summarised from the harmonised guideline on stability testing of new drug substances and products. Frozen-storage products are not accelerated in the usual sense; the guidance substitutes a study of the effect of a short excursion above the intended condition, which is precisely the data a shipped research vial would need and does not have.

Bacteriostatic water, sterile water, and what each is for

Sterile water for injection contains water and nothing else. It is sterile when the container is opened and it has no capacity to remain so, and it supports the growth of any organism introduced subsequently. It is the appropriate diluent for a single-use presentation and the wrong one for anything intended to be entered more than once.

Bacteriostatic water for injection contains benzyl alcohol at nine parts per thousand. Benzyl alcohol inhibits microbial growth, which is what makes a multiple-dose presentation coherent, and it is important to be exact about what that means: a preservative suppresses the proliferation of organisms introduced during use. It does not sterilise a contaminated solution, it does not act instantly, and its effectiveness against a given organism is established by a specific compendial test rather than assumed.

Two further points get lost. Benzyl alcohol is not universally compatible; it has been implicated in the aggregation of certain protein formulations, and compatibility with a given peptide is a question for data rather than for convention. And a preservative system has its own stability: preservative content declines over an in-use period, which is one of the attributes a proper in-use study measures. A diluent choice is therefore a formulation decision with chemical consequences, not a matter of preference between two clear liquids.4

Freezing a solution is not storing it

Freezing a reconstituted vial to extend its life is a common inference and a poor one, for reasons that have nothing to do with temperature and everything to do with what happens during the phase change. As ice forms, solutes are excluded from the crystal lattice and concentrated into a shrinking unfrozen fraction. Local concentration, ionic strength and pH in that fraction can shift dramatically — buffer components crystallise at different points, and a phosphate buffer is notorious for a large pH excursion on freezing.

The ice-water interface is itself a denaturing surface, and interfacial area increases with the number of freeze-thaw cycles. Each cycle presents the peptide with a fresh opportunity to unfold at that interface and aggregate. This is why formulations intended for frozen storage contain cryoprotectants and why lyophilisation exists as a technique at all: the point of drying is to avoid keeping a peptide in a partially frozen aqueous system.

The Journal states the mechanism and declines the recommendation, as this department’s practice requires. What can be said without advising anybody is that freezing a reconstituted solution is a different chemical operation from freezing a dried cake, that its effects are formulation-dependent and not predictable from first principles, and that no in-use study we have seen in this market has examined it. A reader treating the freezer as a pause button is relying on an assumption nobody has tested for that product.

6.54.93.21.600.911.423.934.442.754.265.871.78°C difference
Figure. Gap between mean kinetic temperature and arithmetic mean, by parcel. The gap widens with the height and brevity of the excursion, which is what the exponential weighting exists to capture.

A note on method and sourcing

The regulatory framework in this article is taken from the harmonised guidelines on stability testing and on biotechnological products, read in the original, and from the current compendial chapters on storage definitions, distribution of temperature-sensitive products and stability in dispensing practice. The degradation chemistry is drawn from the peptide and pharmaceutical sciences literature, and where a claim is a generalisation across sequences this piece says so, because sequence dependence is the rule rather than the exception.

The shipment data is ours. Nine parcels, ordered at catalogue prices as ordinary customers, with calibrated loggers placed inside the insulated payload and sampling at five-minute intervals. Eight complete traces and one truncated by a customs hold. We disclose that nine parcels is not a survey, that we did not control the packing operation, and that a single logger cannot characterise a payload with a thermal gradient across it.

Nothing in this department is a recommendation about storing, reconstituting or administering anything. The compounds discussed are sold for research use only and are not approved for human use in any jurisdiction. Corrections and disputes go to standards@compoundjournal.com; documents, traces and certificates readers would like examined go to letters@compoundjournal.com, and we do not identify the source of anything sent to us.

Nobody can buy time, which is why this documentation gap is not going to be closed by a testing service. What can be done immediately is to distinguish a measurement from a convention: to say twelve months at minus twenty, ongoing, rather than two years, and to say that an in-use period has not been established for this product rather than borrowing one from a pen.

References

  1. International Council for Harmonisation. Q1A(R2): Stability Testing of New Drug Substances and Products. 2003.
  2. “Qualification of insulated shippers and interpretation of single-use temperature logger data in distribution.” PDA Journal of Pharmaceutical Science and Technology. 2018;72(4):341–356.
  3. “Surface adsorption losses of peptides at low concentration in glass and polymer containers.” Journal of Pharmaceutical Sciences. 2016;105(9):2617–2626.
  4. United States Pharmacopeia. General Chapter ⟨51⟩ Antimicrobial Effectiveness Testing. USP–NF, Rockville, MD.