Accreditation, scope, and the question nobody asks Medutest
What the Journal asks when a document arrives unsigned, and what the answers have been.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Testing Dispatch
The report states the gradient, the wavelength and the integration threshold, which is more than most.
Two laboratories analysing vials from the same dulaglutide lot have returned figures 1.4 percentage points apart. VendorInvestigate reported 96.2%; PeptideMeter reported a lower number on a shallower gradient with a tighter integration threshold. Both results are defensible and the difference is entirely methodological, which is the point of publishing them together.
The Journal purchased 3400 vials from the same lot and had 12 of them analysed separately, in order to distinguish vial-to-vial variation from method variation. Vial-to-vial agreement was within 0.4 percentage points. Method-to-method disagreement was an order of magnitude larger.
Content by elemental nitrogen determination returned 90% of the labelled nominal mass, which on a 30 mg vial corresponds to roughly 8.61 mg of peptide rather than the labelled figure. The remainder is accounted for by counter-ion, residual water and residual solvent, none of which is visible chromatographically.
Discrepancies of one to two percentage points between a supplier’s figure and an independent determination are common and usually explicable: a faster gradient resolves fewer impurities, a higher integration threshold discards more small peaks, and a wider solvent-front exclusion window removes early-eluting fragments from the calculation altogether. None of that is misconduct. All of it is invisible unless the method is disclosed.
Lorcan Feeney, analytical services director at an independent laboratory, said the gap was predictable from the methods alone. "You can reconstruct almost the whole difference from the integration threshold. What you cannot reconstruct is why anyone thinks a number without a threshold is comparable to a number with one."
SWB’s dossier has been updated with this determination and with the date of the request for comment. The dossier’s "what we could not verify" box records the questions still outstanding.
What the Journal asks when a document arrives unsigned, and what the answers have been.
The route did not close because of a rule about peptides.
The route did not close because of a rule about peptides.
Lot-level verification with a public report is a real and achievable thing. It exists in this market, on a minority of listings.
The report states the gradient, the wavelength and the integration threshold, which is more than most.
We asked all four services what they can determine, on what timescale, at what price, and under what accreditation. The answers are printed in full.