QSC declines, for the 21st time, to name its synthesis house
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Aseptic fill
We asked all four services what they can determine, on what timescale, at what price, and under what accreditation. The answers are printed in full.
The explanation is structural rather than any failure of ambition. A purity run occupies an instrument for between twelve and forty minutes and produces a document the same week. A compendial sterility test requires aseptic transfer of the entire container contents into two growth media, incubation at two temperatures for fourteen days, and a facility qualified for that transfer, because a false positive from the analyst’s own sleeve is worse than no result. The test destroys the sample. Nothing about that sequence fits a service priced for private buyers submitting single vials.
Sterilising-grade filtration through a membrane of 0.22 micron nominal rating is the operation on which aseptic processing rests. The membrane is qualified by challenge with a small bacterium at high concentration under the process conditions, and a filter that permits no passage under that challenge is accepted as sterilising for that fluid.
The critical practice is not the filtration but the integrity test that follows it. A membrane can be damaged during installation, during sterilisation, or by pressure excursions in use, and a damaged membrane looks exactly like an intact one. Bubble point, diffusive flow and pressure hold tests each detect a breach by measuring gas behaviour across a wetted membrane, and a post-use test is the only evidence that the filter was intact while the product was passing through it. A pre-use test alone establishes nothing about the state of the membrane at the end of the run.
This is the question the Journal has found most useful when assessing whether a fill operation is a real one. It is specific, it has a yes or no answer, the answer is recorded in the batch documentation as a matter of course, and it cannot be answered plausibly by anybody who is not actually running the process.
The compendial test proceeds by one of two routes. In membrane filtration, the entire contents of the sampled containers are passed through a retentive membrane which is then divided between two growth media. In direct inoculation, the contents are transferred into the media directly. The media are a fluid thioglycollate medium incubated at thirty to thirty-five degrees for anaerobes and aerobes, and a soybean-casein digest medium incubated at twenty to twenty-five degrees for fungi and aerobes. Incubation runs for fourteen days with periodic examination for visible growth.
The number of containers sampled depends on batch size, and for a parenteral batch above five hundred containers the requirement is twenty. Every one of those twenty is destroyed. Method suitability must be demonstrated separately, because a preserved formulation or an antimicrobial residue can inhibit the very growth the test is looking for, and the bacteriostatic and fungistatic properties of the article have to be neutralised or shown absent before a negative result means anything.1
A reader who takes nothing else from this section should take the sample size. Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim, and it is why the process argument carries the weight.
A dye ingress test can pass a container with a defect large enough to admit an organism, because the dye happened not to travel.
On probabilistic leak testingThe gel-clot method is the oldest and simplest: lysate is combined with the sample, incubated, and the tube inverted. A firm clot that does not slip is a positive. It is a limit test, and by testing serial dilutions it becomes semi-quantitative. Its virtues are robustness and independence from instrumentation; its limitation is resolution.
Turbidimetric methods read the increasing turbidity produced by clotting protein formation, either as an endpoint at fixed time or kinetically as the time to reach a defined turbidity. Chromogenic methods substitute a synthetic peptide substrate that releases a chromophore when cleaved by the activated enzyme, and read absorbance. The kinetic chromogenic variant — measuring the time to a defined absorbance change against a standard curve — is the method of record for most modern release testing, offering quantitation across several orders of magnitude from a small sample volume.
All three are compendial, all three require a demonstration that the sample matrix neither inhibits nor enhances the reaction, and all three are calibrated against an international reference endotoxin rather than against a mass. A result reported without the method and without the inhibition-enhancement result is, once again, a number without a procedure.2
| Question | Answered | Declined | No reply |
|---|---|---|---|
| Fill route: aseptic or terminal | 9 | 4 | 7 |
| Pre-filtration bioburden determined | 7 | 4 | 9 |
| Filter integrity tested post-use | 5 | 4 | 11 |
| Aseptic process simulation performed | 3 | 5 | 12 |
| Endotoxin determined on finished product | 4 | 4 | 12 |
| Questions were sent twice, four weeks apart, to the published contact address of each company. Declined denotes a reply that engaged with the question and refused it; no reply denotes two unanswered messages. Four of the declines cited the research-use-only basis of sale, which the Journal regards as a legally sound answer. | |||
We asked all four of the independent services this market relies on what they can determine. Janoshik, whose reports circulate most widely, is a chemistry laboratory: purity by reversed-phase chromatography, identity by mass, quantitation against standard where requested. Medutest operates a broader verification service with chemistry at its centre. PeptideMeter is likewise a chemistry and verification operation. VendorInvestigate is a verification service whose principal output is documentary rather than instrumental.
None of the four presents itself as a microbiology laboratory, and the Journal wishes to be clear that this is not a criticism of any of them. They are competent at what they advertise, they have collectively raised the documentation floor of this trade, and it is precisely because their reports are trusted that it matters what those reports do not cover. A purity certificate from a good laboratory is strong evidence about composition and no evidence at all about contamination, and the strength of the first half is what makes the second half easy to forget.
Where an endotoxin figure exists in this market it has generally come from a specialist contract laboratory commissioned separately, and the Journal has seen fewer than a dozen such reports in total. Two of them accompanied vials we submitted ourselves.
Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.
We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.
What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.3
The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.
Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.
Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.
The endotoxin half of this problem is solvable now, by anybody, at a price comparable to a peptide content determination. That is the single most practically useful sentence in this article. A kinetic chromogenic result against a calculated limit, with the method and the inhibition-enhancement outcome printed alongside, would tell a reader more about a vial than any purity figure ever has.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
Reported from the analysis, not from a warning notice.
What would make a difference is not a regulator. It is three lines on a certificate, all of which are already known to whoever wrote it.
What happens to traceability when bulk material is subdivided, repackaged and relabelled two or three times before sale.
The report states the gradient, the wavelength and the integration threshold, which is more than most.