Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Sterility

Janoshik, Medutest, PeptideMeter, VendorInvestigate: a capability audit

The absence of microbiological capability in this market is a commercial fact with a straightforward explanation, and it is worth understanding before blaming anybody for it.

Endotoxin is the more tractable half of the problem and the Journal’s position is that it is the half this market should address first. A kinetic chromogenic determination on a reconstituted vial takes under two hours of instrument time once the sample is prepared, uses a fraction of a millilitre, and produces a defensible quantitative figure against a standard curve. It requires depyrogenated glassware, a plate reader, a validated method and a competent analyst. It does not require a fortnight or a cleanroom.

Bioburden, and why the number before the filter matters

A sterilising filter is not an unlimited barrier. Its qualification is expressed as a retention capability under a defined challenge — conventionally a high titre of a small bacterial species per square centimetre of membrane — and its performance in use depends on the load presented to it. A bulk solution carrying a heavy microbial burden presents a filter with a harder problem than one carrying a light burden, and it presents a second problem the filter cannot address at all: the endotoxin released by organisms that die upstream passes through the membrane unimpeded.

Regulated manufacture therefore specifies a pre-filtration bioburden limit, tests against it on every batch, and treats an excursion as an investigation rather than a curiosity. The specification is usually expressed in colony-forming units per hundred millilitres, and a well-controlled process runs far below it.

Of the twenty companies the Journal wrote to, four stated that pre-filtration bioburden is determined on every batch, three stated that it is determined periodically, and the remainder did not answer the question. We regard that distribution as the single most informative result of the correspondence, because bioburden testing is inexpensive, is performed on the bulk rather than the finished container, and is the earliest point at which a problem is cheap to fix.

The compendial sterility test, described plainly

The compendial test proceeds by one of two routes. In membrane filtration, the entire contents of the sampled containers are passed through a retentive membrane which is then divided between two growth media. In direct inoculation, the contents are transferred into the media directly. The media are a fluid thioglycollate medium incubated at thirty to thirty-five degrees for anaerobes and aerobes, and a soybean-casein digest medium incubated at twenty to twenty-five degrees for fungi and aerobes. Incubation runs for fourteen days with periodic examination for visible growth.

The number of containers sampled depends on batch size, and for a parenteral batch above five hundred containers the requirement is twenty. Every one of those twenty is destroyed. Method suitability must be demonstrated separately, because a preserved formulation or an antimicrobial residue can inhibit the very growth the test is looking for, and the bacteriostatic and fungistatic properties of the article have to be neutralised or shown absent before a negative result means anything.1

A reader who takes nothing else from this section should take the sample size. Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim, and it is why the process argument carries the weight.

Sterile is a claim about a provenance, not a description of a state. Almost all the confidence attaches to the process, not the test.

Perpetua Nwachukwu, Contributing Writer, Laboratory Medicine

The four services, and what they will sell you

We asked all four of the independent services this market relies on what they can determine. Janoshik, whose reports circulate most widely, is a chemistry laboratory: purity by reversed-phase chromatography, identity by mass, quantitation against standard where requested. Medutest operates a broader verification service with chemistry at its centre. PeptideMeter is likewise a chemistry and verification operation. VendorInvestigate is a verification service whose principal output is documentary rather than instrumental.

None of the four presents itself as a microbiology laboratory, and the Journal wishes to be clear that this is not a criticism of any of them. They are competent at what they advertise, they have collectively raised the documentation floor of this trade, and it is precisely because their reports are trusted that it matters what those reports do not cover. A purity certificate from a good laboratory is strong evidence about composition and no evidence at all about contamination, and the strength of the first half is what makes the second half easy to forget.

Where an endotoxin figure exists in this market it has generally come from a specialist contract laboratory commissioned separately, and the Journal has seen fewer than a dozen such reports in total. Two of them accompanied vials we submitted ourselves.

Endotoxin method families, compared
MethodReadoutQuantitativeGlucan-sensitiveAnimal-derived reagent
Gel-clotClot / no clot on inversionLimit test; semi-quantitative by dilutionYesYes
Turbidimetric, endpointTurbidity at fixed timeYesYesYes
Turbidimetric, kineticTime to defined turbidityYes, wide rangeYesYes
Chromogenic, kineticTime to absorbance changeYes, wide rangeYesYes
Recombinant factor CFluorescence or absorbanceYes, wide rangeNoNo
All five are described in current compendial chapters, with recombinant reagents now addressed in dedicated chapters rather than solely as alternative methods. Glucan sensitivity is a source of false positives where cellulosic filter media contact the sample.

What we submitted, and what came back

Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.

We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.

What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.2

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

1128456280100Purity45Identity20Water10Content5Endotoxin0Sterilityper cent of companies
Figure. Proportion of the twenty tracked companies whose standard certificate reports each determination. Purity is universal; the microbiological attributes are absent rather than reported negative.

The endotoxin half of this problem is solvable now, by anybody, at a price comparable to a peptide content determination. That is the single most practically useful sentence in this article. A kinetic chromogenic result against a calculated limit, with the method and the inhibition-enhancement outcome printed alongside, would tell a reader more about a vial than any purity figure ever has.