What a batch number is supposed to mean
A document is only as good as the chain that connects it to the material, and most chains here are two or three links longer than the paperwork admits.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Endotoxin
The Journal has read several hundred certificates from twenty companies. We set out what the documents actually cover, and what a reader is filling in from imagination.
We began looking at this seriously after a reader sent us a certificate with a query attached. The certificate reported 99.2 per cent purity for a lyophilised peptide, and the reader wanted to know whether that meant the remaining 0.8 per cent could be bacterial. It is a reasonable question and the answer is that the figure has nothing to do with bacteria in either direction. A vial containing a substantial microbial burden would very probably return a purity figure indistinguishable from a clean one, because the mass involved is far below the integration threshold of any method in commercial use.
Consider what happens physically when a certificate is produced. A few milligrams of lyophilised powder are weighed, dissolved in an aqueous mobile phase with an organic modifier, injected onto a reversed-phase column and separated over a programmed gradient while an ultraviolet detector records absorbance. The output is a trace. Software integrates the areas beneath its features, and the main peak area as a proportion of the total becomes the purity figure.
Every step of that procedure is blind to microbial contamination. A bacterial cell contributes no ultraviolet-absorbing peak at any retention time a peptide method would record. Endotoxin, a lipopolysaccharide, is not usefully detected at the wavelengths used for peptide bond absorbance and would in any case be present at a mass fraction several orders of magnitude below any integration threshold in commercial use. A vial holding a hundred colony-forming units and a vial holding none produce chromatograms that no analyst could distinguish.
This is not a defect of the method. Reversed-phase chromatography is an excellent way of determining what proportion of the chromatographically visible material is the intended species, and that is what it is being asked. The defect is in the reading. A document answering one question is being filed as evidence about five.
The compendial test proceeds by one of two routes. In membrane filtration, the entire contents of the sampled containers are passed through a retentive membrane which is then divided between two growth media. In direct inoculation, the contents are transferred into the media directly. The media are a fluid thioglycollate medium incubated at thirty to thirty-five degrees for anaerobes and aerobes, and a soybean-casein digest medium incubated at twenty to twenty-five degrees for fungi and aerobes. Incubation runs for fourteen days with periodic examination for visible growth.
The number of containers sampled depends on batch size, and for a parenteral batch above five hundred containers the requirement is twenty. Every one of those twenty is destroyed. Method suitability must be demonstrated separately, because a preserved formulation or an antimicrobial residue can inhibit the very growth the test is looking for, and the bacteriostatic and fungistatic properties of the article have to be neutralised or shown absent before a negative result means anything.1
A reader who takes nothing else from this section should take the sample size. Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim, and it is why the process argument carries the weight.
A stated negative is a fact a reader can use. An omission is a space a reader fills with an assumption.
The standing rule in this departmentBecause endotoxin survives sterilisation, glass components require a separate treatment. The standard is dry heat: a tunnel or oven cycle at two hundred and fifty degrees or above, validated to achieve at least a three-log reduction in a deliberately applied endotoxin challenge. Vials emerging from a qualified depyrogenation tunnel are both sterile and pyrogen-free, and they remain so only if the subsequent handling maintains it.
Elastomeric closures cannot take that treatment and are instead washed, siliconised and steam-sterilised by a validated cycle, with endotoxin control achieved by the washing step and specified as a limit per stopper. Water for injection is controlled at source, with a compendial endotoxin specification, and a water system is the commonest origin of a pyrogen problem in an otherwise competent facility.
Depyrogenation is also, in the Journal’s experience of asking, the step most frequently absent from descriptions of small fill operations. Autoclaved vials are sterile. Autoclaved vials are not depyrogenated, and an operation that describes its glass preparation solely in terms of autoclaving has told you something specific about what it has not done. We put this point to eleven correspondents; two said their glass is depyrogenated by dry heat with a validated cycle, and one asked us what depyrogenation was, which we took as a straight answer and a useful one.
| Question | Answered | Declined | No reply |
|---|---|---|---|
| Fill route: aseptic or terminal | 9 | 4 | 7 |
| Pre-filtration bioburden determined | 7 | 4 | 9 |
| Filter integrity tested post-use | 5 | 4 | 11 |
| Aseptic process simulation performed | 3 | 5 | 12 |
| Endotoxin determined on finished product | 4 | 4 | 12 |
| Questions were sent twice, four weeks apart, to the published contact address of each company. Declined denotes a reply that engaged with the question and refused it; no reply denotes two unanswered messages. Four of the declines cited the research-use-only basis of sale, which the Journal regards as a legally sound answer. | |||
The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.
Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.
What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.
The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.
Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.
Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.
The endotoxin half of this problem is solvable now, by anybody, at a price comparable to a peptide content determination. That is the single most practically useful sentence in this article. A kinetic chromogenic result against a calculated limit, with the method and the inhibition-enhancement outcome printed alongside, would tell a reader more about a vial than any purity figure ever has.
A document is only as good as the chain that connects it to the material, and most chains here are two or three links longer than the paperwork admits.
Endotoxin is the more tractable of the two questions, and a kinetic chromogenic determination is neither slow nor exotic. It is simply not on the menu.
The Journal has read several hundred certificates from twenty companies. We set out what the documents actually cover, and what a reader is filling in from imagination.
Duplicate submissions under different names test within-laboratory repeatability, which is a different quantity from between-laboratory reproducibility.
Reported from the analysis, not from a warning notice.
Reported from the analysis, not from a warning notice.