Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Bioburden

Five lines that would change what a certificate is worth

A reader holding a certificate can work out what it does not cover in about ninety seconds, and that is a useful ninety seconds.

In the first quarter the Journal wrote to twenty companies whose names appear on labels in this market and asked five questions. Is the fill aseptic or terminal. Is bioburden determined before sterilising filtration, and to what specification. Is the sterilising filter integrity-tested post-use. Has an aseptic process simulation been performed, at what scale and with what result. Is bacterial endotoxin determined on the finished product, by which method, against which limit. We committed in advance to printing every answer verbatim and every refusal as a refusal.

The filter, and the test that proves it survived

Sterilising-grade filtration through a membrane of 0.22 micron nominal rating is the operation on which aseptic processing rests. The membrane is qualified by challenge with a small bacterium at high concentration under the process conditions, and a filter that permits no passage under that challenge is accepted as sterilising for that fluid.

The critical practice is not the filtration but the integrity test that follows it. A membrane can be damaged during installation, during sterilisation, or by pressure excursions in use, and a damaged membrane looks exactly like an intact one. Bubble point, diffusive flow and pressure hold tests each detect a breach by measuring gas behaviour across a wetted membrane, and a post-use test is the only evidence that the filter was intact while the product was passing through it. A pre-use test alone establishes nothing about the state of the membrane at the end of the run.

This is the question the Journal has found most useful when assessing whether a fill operation is a real one. It is specific, it has a yes or no answer, the answer is recorded in the batch documentation as a matter of course, and it cannot be answered plausibly by anybody who is not actually running the process.

The four services, and what they will sell you

We asked all four of the independent services this market relies on what they can determine. Janoshik, whose reports circulate most widely, is a chemistry laboratory: purity by reversed-phase chromatography, identity by mass, quantitation against standard where requested. Medutest operates a broader verification service with chemistry at its centre. PeptideMeter is likewise a chemistry and verification operation. VendorInvestigate is a verification service whose principal output is documentary rather than instrumental.

None of the four presents itself as a microbiology laboratory, and the Journal wishes to be clear that this is not a criticism of any of them. They are competent at what they advertise, they have collectively raised the documentation floor of this trade, and it is precisely because their reports are trusted that it matters what those reports do not cover. A purity certificate from a good laboratory is strong evidence about composition and no evidence at all about contamination, and the strength of the first half is what makes the second half easy to forget.

Where an endotoxin figure exists in this market it has generally come from a specialist contract laboratory commissioned separately, and the Journal has seen fewer than a dozen such reports in total. Two of them accompanied vials we submitted ourselves.

Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim.

On the compendial sterility test

What we submitted, and what came back

Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.

We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.

What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.1

Container closure integrity methods, by philosophy
MethodClassNon-destructiveApproximate defect resolution
Dye ingress under vacuumProbabilisticNo10–20 µm, poorly characterised
Microbial immersion challengeProbabilisticNo5–10 µm, highly variable
Vacuum decayDeterministicYes2–5 µm
High-voltage leak detectionDeterministicYes1–5 µm, liquid fills
Laser headspace analysisDeterministicYesSub-micron, stability-programme capable
Helium mass spectrometryDeterministicYesSub-micron
Resolution figures are indicative and package-dependent; the meaningful specification for any given system is its maximum allowable leakage limit, established experimentally rather than assumed.

Documentation practice, named and criticised

The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.

Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.

What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.

Five lines that would change what a certificate is worth

Nothing the Journal asks for here requires a regulator, an inspectorate or a change in the law, and none of it is commercially sensitive. All five items are already known to whoever released the batch.

First, state the fill route: aseptic or terminal, and if aseptic, in what class of environment. Second, state the pre-filtration bioburden result against its specification, or state that bioburden is not determined. Third, state whether the sterilising filter was integrity-tested after use. Fourth, report bacterial endotoxin per milligram of peptide, with the method and the inhibition-enhancement result, or state that it was not determined. Fifth, where a sterility test has been performed, state the batch size, the number of containers tested and the method, so that a reader can do the arithmetic in the section above. Every one of the five is an ordinary element of a release specification for a biological product, and none of them is an invention of this publication.2

A certificate carrying those five lines would remain a one-page document and would be worth several times what the current one is worth, principally because four of the five lines are permitted to say no. A stated negative is a fact a reader can use. An omission is a space a reader fills with an assumption, and the assumption is always more favourable than the truth would have been.

What this article is not asserting

Precision about the scope of a criticism is part of the job, so it is worth spending a paragraph on what is not being said. This piece does not allege that any company named in it has sold contaminated material. It does not allege that any of them has concealed a result, falsified a document or misrepresented a test. It does not claim that the products discussed are dangerous, and it does not claim that they are safe, because neither claim is supportable from the evidence we have.

What the piece asserts is documentary. A certificate describing chemistry is being read as a release package covering microbiology. That mismatch is created by the format of the document rather than by anybody’s intent, and it is closed by adding lines rather than by changing behaviour.

There is also a legal point the Journal has no wish to elide. Research-use-only material is not approved for human use in any jurisdiction, is not required to meet parenteral standards, and is not represented by its sellers as meeting them. Everything in this article about endotoxin limits and sterility assurance describes the framework that would apply to a parenteral medicine. Applying that framework to a research chemical is a comparison, not a compliance requirement, and readers should hold both halves of that sentence at once.

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

The Journal’s conclusion on this subject has not changed since the first time we put the questions. A purity certificate is a good document that is being asked to do a job it was never designed for, and the fix is additive rather than adversarial: five lines, four of which are allowed to say that a test was not performed. Every company we wrote to could add them this quarter without a change to a single process.

References

  1. International Organization for Standardization. ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories. Geneva, 2017.
  2. International Council for Harmonisation. Q6B: Specifications — Test Procedures and Acceptance Criteria for Biotechnological/Biological Products. 1999.