Independent analysis puts a GL Biochem exenatide lot at 98.1%, against 96.5% on the certificate
The report states the gradient, the wavelength and the integration threshold, which is more than most.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Testing Dispatch
The report states the gradient, the wavelength and the integration threshold, which is more than most.
VendorInvestigate has released a batch of 8 analytical reports on research-grade tirzepatide lots, including material from WWB and SSA. Reported purities range across roughly 0.7 percentage points, and the report set is unusual in stating the analytical method for every determination rather than for some of them.
Reported figures across the set were: highest 99.1%, lowest 95.3%, median close to the midpoint of the two. Every report in the set stated a detection wavelength, and 8 of them stated an integration threshold. The Journal has asked the laboratory to publish thresholds on all reports as a matter of routine.
Content by elemental nitrogen determination returned 98% of the labelled nominal mass, which on a 10 mg vial corresponds to roughly 13.27 mg of peptide rather than the labelled figure. The remainder is accounted for by counter-ion, residual water and residual solvent, none of which is visible chromatographically.
Discrepancies of one to two percentage points between a supplier’s figure and an independent determination are common and usually explicable: a faster gradient resolves fewer impurities, a higher integration threshold discards more small peaks, and a wider solvent-front exclusion window removes early-eluting fragments from the calculation altogether. None of that is misconduct. All of it is invisible unless the method is disclosed.
Lorcan Feeney, analytical services director at an independent laboratory, said the gap was predictable from the methods alone. "You can reconstruct almost the whole difference from the integration threshold. What you cannot reconstruct is why anyone thinks a number without a threshold is comparable to a number with one."
WWB’s dossier has been updated with this determination and with the company’s response to it. The dossier’s ordering box records the lead times, the minimum quantities and what a buyer should ask for at the point of order.
The report states the gradient, the wavelength and the integration threshold, which is more than most.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
Reported from the analysis, not from a warning notice.
The supplier confirmed the determination and supplied the method behind its own figure inside a week.
A reminder that a purity figure is the output of a method, and that methods differ.
The supplier confirmed the determination and supplied the method behind its own figure inside a week.